GDC PMA-2000 Installation Manual

Power management adapter

Advertisement

Quick Links

PMA-2000 POWER MANAGEMENT ADAPTER
INSTALLATION MANUAL
th
November 13
, 2020

Advertisement

Table of Contents
loading

Summary of Contents for GDC PMA-2000

  • Page 1 PMA-2000 POWER MANAGEMENT ADAPTER INSTALLATION MANUAL November 13 , 2020...
  • Page 2: Table Of Contents

    3.7 Power Supply Connection to the Device Sockets ......... 16 3.8 Power Supply Connection to the Screen Masking System ....16 3.9 Power Supply Connection to the PMA-2000 .......... 17 Software Configuration ................18 4.1 Setting up IP Address ................18 4.2 Adding a new device ................
  • Page 3 1. Introduction CONTACTS AND OFFICES Website Contact Us Worldwide Offices 24/7 Support GDC PMA-2000 INSTALLATION MANUAL - 3 - November 13 , 2020...
  • Page 4: Introduction

    1. Introduction 1 Introduction The PMA-2000 is a power management device designed especially for theatre projection rooms. It provides intelligent power supply management for theatre projection equipment, giving exhibitors the means to achieve a complete unmanned projection system. ▪ Retrofit installation means zero interference with the existing power supply system, making seamless integration possible for theatres under construction or currently in operation.
  • Page 5: Packing List

    2. Packing List 2 Packing List The PMA-2000 package includes two boxes: the main package and the accessories package. The contents are listed under Table 1. PMA-2000 Packing List Sr. No. Description Quantity Photo PMA-2000 Power Management Adapter Mounting Bracket...
  • Page 6 2. Packing List Lighting System Wires (2.5mm - Yellow/ Blue) Equipment Socket Wires (2.5 mm - Red/ Blue) International standard power cord Metal hose Supplementary Parts Multiple and Accessories Table 1 GDC PMA-2000 INSTALLATION MANUAL - 6 - November 13 , 2020...
  • Page 7: Hardware Installation

    The device has two outlet ports on either side for cable connections. Figure 1: Mounting location for PMA-2000 When there is not enough space around the distribution box, the PMA-2000 can be installed above or below the distribution box and the metal hose can be used for wiring, as shown in Figure 2.
  • Page 8: Introduction Of Front Panel And Ports

    The upper half of the device to designed to be a manual control panel and a status display area. The buttons themselves are status light indicators. Illuminated indicator means that the device connected to the corresponding output of the PMA-2000 is powered up, while non-illuminated indicator means that the device is not powered. Due to safety considerations, pressing the individual button will not execute power supply connection/disconnection unless it is pressed concurrently with the ‘Unlock button’...
  • Page 9 The Management Network cable from the cinema control room is first connected to one of these network ports and then routed to the single hall manageable switch via the other network port. In this setup, the PMA-2000 is available on the network in case of power failure to the single hall switch.
  • Page 10: Device Installation And Cabling

    32mm hole opener to cut the hole. Polish the corresponding incoming and outgoing any sharp hole edge to prevent power supply wires according to the device breakage of any wires. labels. GDC PMA-2000 INSTALLATION MANUAL - 10 - November 13 , 2020...
  • Page 11 3. Hardware Installation Step 7: Connect network cable and power cord for the PMA device. GDC PMA-2000 INSTALLATION MANUAL - 11 - November 13 , 2020...
  • Page 12: Power Supply Connection To The Projector

    2. Connect PMA's ‘live wire out’ with the original live wire at the lower end of the projector circuit breaker and identify with 1AWG mark. Figure 6: Projector circuit breaker connection GDC PMA-2000 INSTALLATION MANUAL - 12 - November 13...
  • Page 13: Power Supply Connection To The Ventilation System

    2. Connect PMA's ‘live wire out’ with the original live wire at the lower end of the exhaust fan circuit breaker, and identify with 2, 3 and 4AWG marks. Figure 7: Ventilation System circuit breaker connection GDC PMA-2000 INSTALLATION MANUAL - 13 - November 13...
  • Page 14: Power Supply Connection To The Audio System

    2. Connect PMA's ‘live wire out’ with the original live wire at the lower end of the audio system circuit breaker, and identify with 5AWG mark. Figure 8: Audio System circuit breaker connection GDC PMA-2000 INSTALLATION MANUAL - 14 - November 13...
  • Page 15: Power Supply Connection To The Lighting System

    Note: If a leakage protection switch is in use, the neutral wire can only be connected to this specific neutral wire port on circuit breaker. It cannot be connected to the public neutral wire port or else the circuit breaker will be triggered. GDC PMA-2000 INSTALLATION MANUAL - 15 - November 13...
  • Page 16: Power Supply Connection To The Device Sockets

    3.8 Power Supply Connection to the Screen Masking System The connection method is the same as that of the Ventilation system. Please refer to Section 3.4 for the power supply connection of the Ventilation system. GDC PMA-2000 INSTALLATION MANUAL - 16 - November 13...
  • Page 17: Power Supply Connection To The Pma-2000

    3. Hardware Installation 3.9 Power Supply Connection to the PMA-2000 The PMA-2000 uses a regular 220V power supply. Thus, only a three-pin international standard cable (with quick-connecting terminals) is required. 1. On the PMA, connect a 3-pin cable to the ‘system power supply’.
  • Page 18: Software Configuration

    IP modification main interface. Figure 12: Modifying the IP Address of PMA Enter the IP address of the PMA-2000 in the 'IP address' field and leave the ‘Password’ field blank. Click 'OK' to enter the IP modification page. After accessing to the page, first modify the gateway address, click 'Update' to save.
  • Page 19 Modify the IP Address & click the Update button on the right Generate the MAC Address by clicking on Generate random MAC address button & click the Change button on the right Table 2 GDC PMA-2000 INSTALLATION MANUAL - 19 - November 13 , 2020...
  • Page 20: Adding A New Device

    4. Software Configuration 4.2 Adding a new device PMA-2000 can be added and configured at the Screen tab of ‘GDC TMS-2000 Software’. Click on ‘Automation’ under Device sub-tab. A window will pop up. Select the device Model, fill in the device information,...
  • Page 21: Remote Control Of Power Connection/Disconnection

    Select the PMA1000 Controls sub-tab, individual power supply circuit can then be controlled. Figure 16: PMA-2000 remote controls Note: The Blue timeline represents the screening period. If the current time is within the screening period, only power connection operation is available and power disconnection operation is invalid.
  • Page 22 Contact Us GDC Technology manufacturing facility is ISO 9001:2015 certified. Copyright © 2023 GDC Technology Limited. All Rights Reserved. All trademarks listed in this manual are properties of their respective owners. Specifications are subject to change without notice due to ongoing product development and improvement.

Table of Contents