FLEXTEC
®
350XP AND FLEXTEC 350X CONSTRUCTION
CASE FRONT CONTROL - CONSTRUCTION
1. Amperage LCD Display
2.
Thermal LED: A yellow light that comes on when an over
temperature situation occurs. Output is disabled until the
machine cools down. When cool, the light goes out and
output is enabled.
3.
CrossLinc Communication Indicator: When green, the power
source is connected to a feeder via CrossLinc.
4.
Process Indicator LEDs: Red LEDs that indicate which of the
CC-GTAW, CC-SMAW, CV, and CV-Innershield.
5. Process Indicator Switch: Momentary rocker switch to select
weld modes.
6. Optional TIG Solenoid Outlet: Remove plug button to install
K5527-1 TIG Solenoid Kit.
7.
12-Pin Remote: Circular connector for attaching optional remote
control devices.
8.
Positive and Negative Welding Output Connection
9.
Power Switch: Controls input power to the Flextec 350XP
Construction.
®
FIGURE A.1B
10. Output Control Dial: Sets the Output Current or Voltage for the
selected Weld Process.
11. Local/Remote Selector Toggle Switch: Choose machine
output to be controlled locally through the output control
knob or remotely via a remote device connected to the 12-
pin connector (i.e. hand amptrol or K870 foot amptrol). A
device connected through CrossLinc technology will override
this setting.
12. Arc Force Control Dial: Full range selection of arc force from
-10 to +10.
13. Hot Start Control Dial: Full range selection of hot start from
0 to 10.
14. Voltage LCD Display
15. VRD LED Indicators
A-6