Input can be used as pulse counters (see settings chapter).
3.2 Output
Contact mode
SPDT
Max. power commutable
2000VA
Maximum switching voltage
Max. current
8A
250Vac~
The output has pulse capability (minimum pulse duration is 100ms, maximum around 100 minutes), so, instead to send two different commands (one to turn on and
one to turn off the ouput), is possible to send a duration command.
As application example, to safely turn on an output, send a ON-pulse command for a defined time (for example, for the maximum allowed interval), and before the
expiring time, another ON-pulse command (making a kind of watchdog) if the output still needs to be ON, or a simply OFF command if you want to turn it off.
3.2.1 Time schedule
It is possible to program the device with a weekly calendar, based on day of the week and time, to turn ON and OFF the output at a defined time:
and generate and XLS file that can be downloaded by downlinks:
3.3 Wiring examples
Load connected to the same supply of the sensor, connected to the relay output (normally open contact):