1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Mounting of the sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.3 Installation in Zone 2: particular conditions . . . . . . . . . . . . . . . . . . .3
3.4 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .4
5
5.1 LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.2 Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.3 Operating principle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.4 Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.2 Start configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.3 Sensor configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8.4 Actuator configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
9
9.2 Guidelines for installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
10 EU Declaration of conformity
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country-specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
EN
PROTECT SRB 200EXi-1A
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB 200EXi-1A and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal SRB 200EXi-1A

  • Page 1: Table Of Contents

    Set-up and maintenance Further technical information can be found in the Schmersal 6.1 Functional testing........5 catalogues or in the online catalogue on the Internet: 6.2 Maintenance .
  • Page 2: Warning About Misuse

    Operating instructions Safety-monitoring module PROTECT SRB 200EXi-1A The information contained in this operating instructions manual is The safety function is defined as the opening of release 13-14 when provided without liability and is subject to technical modifications. the inputs S11-S12 or S21-S22 are opened. The safety-relevant current...
  • Page 3: Safety Classification

    Operating instructions Safety-monitoring module PROTECT SRB 200EXi-1A Switching capacity of the safety contacts: 13-14: The PFH values of 2.00 x 10 /h apply to the combinations of contact max. 230 V, 3 A ohmic load (current through enabling contacts) and number of switching...
  • Page 4: Dimensions

    Signalling outputs must not be used in safety circuits. 0V X1 X3 S11 S12 S21 S22 5.3 Operating principle • The SRB 200EXi-1A is a dual-channel safety-monitoring module for 200EXi monitoring emergency stop command devices, guard door monitors and magnetic safety switches.
  • Page 5: Set-Up And Maintenance

    Operating instructions Safety-monitoring module PROTECT SRB 200EXi-1A 8. Appendix 8.1 Wiring examples S11 S12 S21S22 Dual-channel control, shown for a guard door monitor with two 0V X1 X3 0V X1 X3 0V X1 X3 S11 S12 S21S22 S11 S12 S21S22 S11 S12 S21S22 position switches where one has a positive break contact;...
  • Page 6: Sensor Configuration

    Operating instructions Safety-monitoring module PROTECT SRB 200EXi-1A Dual-channel guard door monitoring circuit with interlocking device to ISO 14119 (see Fig. 13) • At least one contact with positive break required. • Wire breakage and earth leakage in the control circuits are detected.
  • Page 7: Actuator Configuration

    According to IEC/EN 60079-11 (ABTN NBR IEC 60079-11), following devices from K.A. Schmersal GmbH & Co. KG can be used: the following must be observed for the installation: a distance of ≥ 6 mm must be observed between the terminals of the...
  • Page 8 Philip Schmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone:...

Table of Contents