Operating Floor Tool - Castex PX-1500HPH Operator And Parts Manual

Carpet extractor with heat
Table of Contents

Advertisement

OPERATION
6. Attach vacuum and solution hose to hose
connectors at front of machine then to floor or
hand tool (Figure 5).
7. Turn "PUMP" and "HEATER" switches off when
solution reaches up to a maximum temperature of
approximately 66_C (150_F). Rotate preheat/clean
knob to read "CLEAN" (Figure 6). While operating,
the "CLEAN" mode will raise the existing solution
temperature approximately 11_C (20_F) at the
spray tips. Example: A solution tank temperature
of 66_C (150_F) will increase to a maximum
temperature of approximately 77_C (170_F) at
the spray tips.
ATTENTION: DO NOT switch from "PREHEAT" to
"CLEAN" mode when pump switch is activated,
pump and gauge damage may occur (not covered
by warranty). Always turn pump switch off before
turning preheat/clean knob.
6
FIG. 4
FIG. 5
FIG. 6
Home
Find... Go To..
NOTE: In order to get optimum water heat at spray
tips while operating, keep preheat/clean knob in
"CLEAN" mode. Cleaning in "PREHEAT" mode will not
harm machine, this will only prevent optimum water
heat at spray tips.

OPERATING FLOOR TOOL

FOR SAFETY: Do not operate machine unless
operator manual is read and understood.
NOTE: Vacuum carpet before cleaning.
1. Activate "VACUUM", "PUMP" and "HEATER"
switches.
NOTE: Be certain that circuit indicator light is on to
verify that two separate circuits are being used.
2. Place floor tool so bottom of glide plate or
stainless steel shoes are parallel to floor. Squeeze
trigger and apply downward pressure on floor tool
head and slowly pull tool backwards using both
hands. Release trigger 152 mm (6 in) from end of
stroke (Figure 7).
WARNING: Flammable materials or reactive
metals can cause explosion or fire. Do not pick
up.
3. Push floor tool forward over same path with trigger
released when returning for next stroke. Continue
this pull and push method with a slight overlap of
each stroke.
NOTE: For heavily soiled areas, repeat stroke or
change angle of stroke.
ATTENTION: Do not allow water or foam to enter
vacuum motor. Float shut-off screen will not stop
foam intake and vacuum motor damage will result
(not covered by warranty). If foam develops,
remove rear clear lid and pour 30 ml (1 oz) of
anti-foam solution into recovery tank.
4. When finished cleaning, turn off switches and
drain recovery tank (See DRAINING MACHINE).
FIG. 7
PX-1500HPH (04–99)

Advertisement

Table of Contents
loading

This manual is also suitable for:

608218

Table of Contents