GENERAL DATA

Figure 19: Two-Port Heat Recovery Unit.
Heat recovery units can only be used with LG systems piped for heat recovery operation.
Table 16:
Model
Number of Ports
Max. Connectable No. of Indoor Units
Max. Connectable No. of Indoor Units on each port
Max. Port Capacity (each port)
Max. Unit Capacity (sum of ports)
Net Weight
Dimensions (W x H x D)
Casing
To Indoor Units
Connecting Pipes
To Outdoor
Units
Insulation Material
Minimum Circuit Amps (MCA)
Current
Maximum Fuse Amps (MFA)
Power Supply
Table 17: Heat Recovery Unit Electrical Data.
Unit Model No.
PRHR022A
PRHR032A
PRHR042A
76 | HRU PRODUCT DATA
Figure 20: Three-Port Heat Recovery Unit.
Btu/h
Btu/h
lbs.
inches
Liquid Pipe (inches)
Vapor Pipe (inches)
Liquid (inches)
Low-pressure Vapor (inches)
High-pressure Vapor (inches)
V / Hz / Ph
208-230 / 60 / 1
208-230 / 60 / 1
208-230 / 60 / 1
©
Figure 21: Four-Port Heat Recovery Unit.
PRHR022A
PRHR032A
2
3
16
24
8
8
54,000
54,000
192,000
192,000
40
45
17-7/8 x 8-5/8 x 18-15/16
Galvanized steel plate
3/8
5/8
3/8
1/2
7/8
1-1/8
3/4
7/8
Polyethylene
0.1
0.15
15
1Ø, 208-230V, 60Hz
Input (kW)
Cooling
0.026
0.033
0.040
PRHR042A
4
32
8
54,000
192,000
49
5/8
1-1/8
7/8
0.2
Heating
0.026
0.033
0.040