Download Print this page

HP StorageWorks 2312 Replacement Instructions

Modular smart array dc power supply

Advertisement

Quick Links

HP StorageWorks
2312/2324 Modular Smart
Array DC power supply
replacement instructions
© Copyright 2008 Hewlett-Packard Development Company, L.P.
First edition: November, 2008
The information in this document is subject to change without
notice.
Printed in China
www.hp.com
500919-001
About this document
This document details procedures for replacing a failed DC power
supply in an HP StorageWorks 2000 Family Modular Smart Array.
Before you begin
CAUTION:
Parts can be damaged by electrostatic discharge. Use proper
anti-static protection:
Keep the replacement component in the ESD bag until needed
Wear an ESD wrist strap grounded to an unpainted surface
of the chassis.
If an ESD wrist strap is unavailable, touch an unpainted surface
of the chassis before handling the component.
Never touch connector pins.
Verifying component failure
Check the DC Voltage/Fan Fault/Service Required (bottom) LED:
Amber = Fault condition
Disconnecting a DC power cable
IMPORTANT:
Use only the DC power cables provided with your product.
1.
Verify that the main breaker to the rack is shut off prior to
disconnecting any DC connections.
2.
Verify that all enclosure power switches are off.
3.
Loosen the cable-locking screws attaching the D-shell connector to
the power supply.
4.
Disconnect the power cable from the power supply.
5.
Turn on the main breaker to the rack.
Removing a power supply
1.
Turn the thumbscrew until it is disengaged from the module.
2.
Rotate the latch downward to disconnect the internal connector,
and slide the module out.
Page 1

Advertisement

loading

Summary of Contents for HP StorageWorks 2312

  • Page 1 HP StorageWorks About this document 2312/2324 Modular Smart This document details procedures for replacing a failed DC power supply in an HP StorageWorks 2000 Family Modular Smart Array. Array DC power supply replacement instructions Before you begin CAUTION: Parts can be damaged by electrostatic discharge. Use proper anti-static protection: •...
  • Page 2 Turn on the enclosure power switches. Verifying component replacement After replacing the module, check that the Input Power Good LED is on and the DC Voltage/Fan Fault/Service Required (bottom) LED is off. Additional information See the MSA2000 web site: http://www.hp.com/go/msa2000. Page 2...