Vaillant ecoTEC plus VUI Installation And Maintenance Instructions Manual page 53

Table of Contents

Advertisement

Code
Parameters
D.058
Activation of solar post-heating for VUW
boilers;
Switch hot water mode
D.060
Number of temperature limiter shut-
downs
D.061
Number of ignition device cutoffs
D.064
Average ignition time
D.065
Maximum ignition time
D.067
Remaining burner anti-cycling time
D.068
Unsuccessful ignitions at 1st attempt
D.069
Unsuccessful ignitions at 2nd attempt
D.070
Set diverter valve position
D.071
Target value maximum heating flow tem-
perature
D.072
Internal pump overrun after cylinder
charging
D.073
Warm start target offset
D.074
actoSTOR Anti-legionella function
D.075
Max. charging time for domestic hot
water cylinder without independent con-
trol system
D.076
Device specific number
D.077
Limit on cylinder charging output
in kW
D.078
Limit on cylinder charging temperature
in °C
D.080
Operating hours, heating
D.081
Operating hours, hot water generation
D.082
Number of burner start-ups in heating
mode
D.083
Number of burner start-ups in hot water
mode
D.084
Maintenance indicator: Number of hours
until the next maintenance
D.088
Start delay for hot water draw-off detec-
tion via impeller
11.1 Diagnostics codes (continued)
Installation and maintenance instructions ecoTEC plus 0020134833_01
Adapting the boiler to the heating installation
Adjustable values
Solar post-heating mode deactivated
Hot water activation target value minimum 60 °C
Number of shutdowns
Number of unsuccessful ignitions in the last attempt
In seconds
In seconds
In minutes
Number of unsuccessful ignitions
Number of unsuccessful ignitions
Normal operating mode
Mid-position (parallel operation)
Continuous heating adjustment
40 to 80 °C
Adjustable from 0 - 10 minutes in increments of 1
minute
Adjustable from -15 K to 5 K
OFF, ON
20 - 90 min
17 = VUI 937
Limit on cylinder charging output
in kW
55 °C - 80 °C
Note: The chosen value must be at least 15 K or 15 °C
above the set cylinder target value.
In hours (h)
In hours (h)
Number of start-ups
Number of start-ups
Setting range: 0 to 3000 hrs and "---" for deactivated
1.5 l/min and no delay,
3.7 l/min and 2 s delay
11
Factory set-
Your own
ting
setting
Solar post-
heating mode
deactivated
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Normal oper-
ating mode
75 °C
2 mins
0
ON
45 mins
Not adjustable
75 °C
Not adjustable
Not adjustable
Not adjustable
Not adjustable
"---"
1.5 l/min and
no delay
53