Vaillant ecoTEC plus VUI Installation And Maintenance Instructions Manual page 51

Table of Contents

Advertisement

Code
Parameters
D.000
Heating partial load
D.001
Overrun time of internal heating pump
for heating mode
D.002
Max. burner anti-cycling time heating
at 20 °C flow temperature
D.003
Outlet temp. actual value
D.004
Measured value of hot water sensor
D.005
Flow temperature target value (or
return target value)
D.006
Hot water temperature target value
D.007
Warm start temperature target value
D.008
Room thermostat at terminal RT
D.009
Target value from external eBus con-
troller
D.010
Status of internal heating pump
D.011
Status of external heating pump
D.012
Status of cylinder charge pump
D.013
Status of hot water circulation pump
D.014
Target pump speed (high-efficiency
pump)
D.015
Actual pump speed (high-efficiency
pump)
D.016
Room thermostat 24 V DC open/
closed
D.017
Heating flow/return regulation
changeover
D.018
Pump operating mode setting
D.019
Operating mode of 2-stage pump
D.020
Max. setting for cylinder target value
D.022
Hot water requirement via C1/C2,
impeller or APC
D.023
Summer/winter operating mode (heat-
ing on/off)
D.025
Hot water generation enabled by
eBUS controller
11.1 Diagnostics codes
Installation and maintenance instructions ecoTEC plus 0020134833_01
Adapting the boiler to the heating installation
Adjustable values
Adjustable heating partial load in kW
Auto: Boiler automatically adjusts max. partial load to cur-
rent system demand
1 - 60 min
2 - 60 min
In °C
In °C
In °C, max. of the value set in d.071, limited by an eBUS
controller if connected
35 to 65 °C
40 to 65 °C
Room thermostat open (no heat requirement)
Room thermostat closed (heat requirement)
In °C
On, Off
On, Off
On, Off
On, Off
Not relevant
Not relevant
Heating mode Off/On
Control type: flow, return
Comfort (continuously operating pump)
Eco (intermittently operating pump)
Setting for operating mode of 2-stage pump:
0 = Burner operation = stage 2, Flow/overrun = stage 1;
1 = Heating + Overrun = stage 1, Hot water = stage 2,
2 = Like 1, but rotational speed during heating mode
depending on heating partial load,
3 =Always stage 2
4 = Rotational speed during heating mode depending on
heating partial load, otherwise always stage 1
Setting range: 50 °C - 65 °C
On, Off
Heating on, heating off (summer mode)
On, Off
11
Factory set-
Your own
ting
setting
Auto
5 min
20 min
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Flow
Eco
2
65 °C
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
51