OmniRx Service Guide
Includes G4 Upgrade and Service
Instructions
67-2023 Rev F

Advertisement

Table of Contents
loading

Summary of Contents for OmniCell G4

  • Page 1 OmniRx Service Guide Includes G4 Upgrade and Service Instructions 67-2023 Rev F...
  • Page 2 This guide and accompanying software and/or hardware described in it are protected under copyright laws and may not be copied, wholly or in part, without the express written consent of Omnicell, Inc. The same proprietary and copyright notices must be attached to any permitted copies as were attached to the original documents.
  • Page 3: Table Of Contents

    Pharmacy Drawer Removal........... . 3-8 OmniRx G4 Console Upgrade .
  • Page 4 Set the G4 Sled on the OmniRx Frame ....... . .
  • Page 5 ..........Feedback-1 © 2011 Omnicell, Inc.
  • Page 6 Table of Contents OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 7: Electronics Sled

    4. Lift the console from the rear of the OmniRx, then prop it up. Caution: Use an ESD wrist band while working inside the sled. 5. Disconnect the black battery cable. Figure 1-1. Battery cable © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 8: Lcd Screen Removal

    5. Tilt the LCD assembly forward and disconnect the cables from the back of the LCD assembly. a. Disconnect the inverter to power cable. b. Disconnect the flat panel cable. 6. Remove the LCD assembly from the LCD housing. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 9: Speaker Removal

    Figure 1-4. Disconnect the speaker cable from the motherboard 3. Remove the two screws that hold the speaker in place using a Torx T10 screwdriver. Figure 1-5. Remove the speaker 4. Disconnect the speaker from the console top. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 10: Printer Removal

    Figure 1-6. Open the printer cover 3. Remove the paper from the printer. 4. Push the platen lever to the left to the disengaged position. Figure 1-7. Turn the platen lever OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 11 Figure 1-8. Remove the printer assembly screws 6. Remove the printer assembly. 7. Remove the four screws that secure the lower assembly to the frame. Figure 1-9. Remove the lower assembly screws © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 12 8. Disconnect the printer ribbon cable and the printer data cables from the printer PC Board. Figure 1-10. Remove the printer cables 9. Remove the printer. Figure 1-11. Remove the printer OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 13: Aps Printer

    1. Open the printer cover by pushing the black release mechanism toward the rear of the machine and lifting the cover. Figure 1-13. Open the printer cover 2. Remove the paper from the printer. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 14 4. Remove the four screws (two on each side) that secure the printer assembly to the cover. Figure 1-15. Remove the Screws Securing the Printer Assembly 5. Remove the printer assembly. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 15 Figure 1-16. Remove the lower assembly screws (top screws partially hidden) 7. Disconnect the four printer cables from the printer PC Board. Figure 1-17. Remove the printer cables: (a) ribbon cable (b) 2 data cables power cable) © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 16: Keyboard Service

    10. Lift the card off the frame slightly, then remove the printer ribbon cable. Keyboard Service 1. Disconnect all console cables. 2. Remove the console and set it upside down in a work area. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 17: Ps/2 Keyboard

    Figure 1-20. Remove the nuts that secure the keyboard cover to the tray 2. Remove the keyboard cover. Figure 1-21. Remove the keyboard cover 3. Remove the keyboard from the tray. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 18 8. Replace the keyboard cover. 9. Replace the screws that secure the keyboard cover to the tray. 10. Set the console back in place, then prop it up. 11. Re-connect all the cables. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 19: Usb Keyboard

    Re-assemble the parts into the bracket. 4. Attach the bracket back on the console. 5. Attach the cables. 6. Set the console back in place, then prop it up. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 20: Pc Tray Upgrade

    1. Disconnect the LAN cable and the AUX cables from the rear of the electronics sled. Figure 1-25. Location and labels for LAN and AUX cable connections on CT PC tray OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 21 Fan power cable (if applicable) Printer cable (free cable from any clips) j. Cabinet power/comm cable k. wireway cable Figure 1-26. Location of cables on the CT PC tray with PowerCom2 board © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 22: Powercom3 Tray

    1. Place the PowerCom3 tray into position inside the electronics sled. 2. Turn the two 1/4-turn fasteners securing the electronics tray clockwise to lock the tray into place. Figure 1-28. Place the CT PC tray into the OmniRx OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 23 Figure 1-30. Connect the printer cable to J27 of the motherboard Note: Ensure that the red wire is connected closest to Pin 1. 5. Connect the fan power cable to J17 on the UPS board (if applicable). © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 24 Figure 1-31. Connect the speaker cable to J45 of the motherboard 7. Connect the keyboard cable to port J42 on the motherboard. Figure 1-32. Connect the keyboard cable to J42 of the motherboard OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 25 Figure 1-33. Connect the touch screen data cable to J2 of the motherboard 9. Connect the inverter cable (backlight) to J32 on the motherboard. Figure 1-34. Connect the backlight cable to J32 of the motherboard © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 26 Insert card reader power cable pins into the disk drive power connector. d. Align the red-stripe pin to the red cable and the gray-stripe pin to the gray cable in next spot. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 27: Standardization Changes

    Electronics Sled 1-21 Standardization Changes Standardization Changes To standardize the peripherals that Omnicell products use, the Seiko printer and PS/2 keyboards are being replaced by APS printers and USB keyboards with a numeric pad. The console swapped out in this procedure.
  • Page 28 1-22 Electronics Sled Final Steps OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 29: Frames And Wireways

    3. Slide the cover to the right and remove the cover. 4. Remove all the drawers from the OmniRx. See “Pharmacy Drawer Removal” on page 3-8. Figure 2-1. Remove the drawers from the OmniRx © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 30 Figure 2-2. Remove the drawer rails 6. Remove the two screws on the front of the frame that help secure the wireway. Figure 2-3. Remove the two wireway screws on the front of the OmniRx OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 31 SPC board to the wireway. Figure 2-5. Remove the ribbon cable and remove the SPC board from the wireway 10. Remove the SPC board from the wireway. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 32: Manual Override Cable Service

    1-14. 9. Remove the four screws that secure the cable cover bracket. Figure 2-6. Remove the four screws that secure the cable cover bracket to the frame 10. Remove the bracket. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 33 Figure 2-7. Remove the two screws that secure the manual override cable to the frame 12. Remove the red handle on the front of the manual override cable. Figure 2-8. Remove the red handle on the manual override cable © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 34 Figure 2-9. Remove the nut that secures the manual override cable to the frame. 14. Remove the screw that secures the manual override cable to the manual override assembly. Figure 2-10. Remove the screw that secures the manual override cable to the frame OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 35: Replacement

    11. Replace the electronics sled and reattach all cables that had been removed. 12. Close the lid to the electronics tray. 13. Feed the printer paper through the printer. 14. Power up the OmniRx cabinet. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 36 2-8 Frames and Wireways Manual Override Cable Service OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 37: Drawers

    These drawers are used to contain controlled substances. Omnicell locking lid drawers provide the highest security. Users can only access one bin at a time which contains the pre-selected medication. All other bin lids remain locked. Special censors generate audible and visual feedback if entry is attempted into bins that are not pre-selected.
  • Page 38: Matrix Drawers

    3. Add the dividers to the bin liner. The dividers should snap into the bottom of the drawer and the sides of each bin liner quadrant. 4. Use the gray circular labels provided with the kit to cover any un-used divider slots in the bin liner. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 39: Lit Matrix Drawers

    (OMD4) is the same a regular double deep drawer. The OMD4 can replace an existing double deep drawer or it would replace two single deep drawers. 1. Perform a graceful shutdown of the electronic sled. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 40: Matrix Drawers Labels

    The bottom of the bin liner on any matrix drawer is numbered according to its type (i.e. 1-96, 1- 24, 1-4). These numbers are used to identify bin locations for the drawer. The drawer will be numbered by using the lowest number in a specific bin. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 41: Supply Drawer Installation

    2. Remove the cover by pushing it to the right and lifting it off. 3. Remove any false drawer front by removing the two screws securing the false drawer front using a Torx T15 screwdriver. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 42 10. Replace the slide to the slide mounting bracket with three screws using a Torx T15 screwdriver. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 43 Use the two screws provided with a Torx T10 screwdriver. 14. Close the drawer and replace the pharmacy manual override cover. 15. Power up the cabinet. 16. Program the drawer at the OmniSupplier in Omni Configurations. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 44: Pharmacy Drawer Removal

    5. Remove the two screws securing the drawer controller cable cover to the cable clamps using a Torx T10 screwdriver. Figure 3-8. Remove the Controller Cable Cover OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 45 7. Push the release levers on either side of the drawer up or down to release the drawer. Figure 3-10. Push the Release Levers to Release the Drawer 8. Remove the pharmacy drawer from the module. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 46 3-10 Drawers Pharmacy Drawer Removal OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 47: Omnirx G4 Console Upgrade

    OmniRx G4 Console Upgrade This chapter provides detailed instructions on how to upgrade the OmniRx to the new G4 console. Tools List The following tools are required to install the electronics tray:  T8 Torx Driver  T10 Torx Driver ...
  • Page 48: Remove The G3 Sled

    4-2 OmniRx G4 Console Upgrade Remove the G3 Sled Remove the G3 Sled 1. Disconnect the battery cable. Figure 4-1. Battery cable 2. Disconnect the LAN cable and any peripheral cables from the rear of the electronics sled. Figure 4-2. Location and labels for LAN and AUX cable connections on CT PC tray OmniRx Service Guide/67-2023 Rev F ©...
  • Page 49 OmniRx G4 Console Upgrade 4-3 Remove the G3 Sled 3. Disconnect the wireway cable from the J3 of the PowerCom3 Board Figure 4-3. Disconnect the wireway cable from J3 of the PowerCom3 board 4. Disconnect the printer cable from J27 on the motherboard.
  • Page 50 4-4 OmniRx G4 Console Upgrade Remove the G3 Sled 6. Disconnect the speaker cable from port J45 on the motherboard. Figure 4-5. Disconnect the speaker cable from J45 of the motherboard 7. Disconnect the keyboard cable from port J42 on the motherboard.
  • Page 51 OmniRx G4 Console Upgrade 4-5 Remove the G3 Sled 8. Disconnect the touch screen data cable from J2 on the motherboard: Figure 4-7. Disconnect the touch screen data cable from J2 of the motherboard 9. Disconnect the inverter cable (backlight) from J32 on the motherboard.
  • Page 52 4-6 OmniRx G4 Console Upgrade Remove the G3 Sled 10. Disconnect the brightness control cable from J31 on the motherboard. Figure 4-9. Disconnect the contrast cable from J31 of the motherboard 11. Disconnect the LCD data cable from J37 on the motherboard Figure 4-10.
  • Page 53: Remove The Sled

    OmniRx G4 Console Upgrade 4-7 Remove the G3 Sled 13. Remove the existing lid from the OmniRx. Figure 4-11. Remove the OmniRx lid Remove the Sled 1. Loosen and remove the thumbscrews that secure the tray to the OmniRx frame.
  • Page 54 4-8 OmniRx G4 Console Upgrade Remove the G3 Sled 2. Remove the CTPC tray from the OmniRx. Figure 4-13. Remove the sled OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 55: Prepare The Omnirx For Install Of The G4

    OmniRx G4 Console Upgrade 4-9 Prepare the OmniRx for Install of the G4 Prepare the OmniRx for Install of the G4 1. Clean the exposed OmniRx surface. Ensure that the surface is flat and smooth. Remove any large objects from the surface. Use a towel to wipe off any dust or small objects that may have been left behind.
  • Page 56 4-10 OmniRx G4 Console Upgrade Prepare the OmniRx for Install of the G4 2. Use a pair of pliers and grab the lid alignment tab as close to the base of the OmniRx frame as possible. Important: Ensure that the tab breaks off as close to the frame lid as possible.
  • Page 57 OmniRx G4 Console Upgrade 4-11 Prepare the OmniRx for Install of the G4 4. Place kapton tape over the opening, which will cover the jagged edge. Figure 4-17. Cover the opening with tape 5. Use your finger, a screw driver or any other tool that will work and bend the tape into the underside of the opening.
  • Page 58 8. Secure the override cable underneath the side rail of the Rx frame to ensure that it does not get pinched when installing the G4 console. If it will not stay, use tape to keep it secured. Figure 4-20. Secure the override cable under the side of the Rx frame OmniRx Service Guide/67-2023 Rev F ©...
  • Page 59: Add The G4 Console

    G4 sled is added. Add the G4 Console 1. Lift the G4 console onto the OmniRx frame, leaving the wireway cable exposed. Figure 4-21. Place the G4 console on the OmniRx with the wireway cable free © 2011 Omnicell, Inc.
  • Page 60 Add the G4 Console 2. Feed the wireway cable through the side of the console frame. Figure 4-22. Feed the wireway cable through the side of the G4 sled 3. Pull the wireway cable through the rear of the console opening.
  • Page 61: Secure The Console To The Omnirx Frame

    Secure the Console to the OmniRx frame Once the eBox cables are securely connected, the next step will be to secure the G4 console to the OmniRx frame. There are two screws and two fasteners that need to be tightened to secure the console to the frame.
  • Page 62 4-16 OmniRx G4 Console Upgrade Add the G4 Console 1. Twist the quarter-turn wingnut fasteners to secure the G4 console to the frame base. Figure 4-25. Turn the right side wingnut fastener to secure the console to the base Figure 4-26. Turn the left side wingnut fastener to secure the console to the base OmniRx Service Guide/67-2023 Rev F ©...
  • Page 63 2. Secure the screw in the right rear of the console. Use a small ratchet and a Torx T30 bit. Figure 4-27. Secure the right side of the G4 console to the OmniRx frame 3. Secure the screw in the left rear of the console. Use a small ratchet and a Torx T30 bit.
  • Page 64: Insert Printer Shelf

    4-18 OmniRx G4 Console Upgrade Add the G4 Console 4. Add the two screws in the printer bay that secure the console to the frame. Figure 4-29. Secure the console to the frame Insert Printer Shelf 1. Load the shelf into the printer bay, as shown in Figure 4-30.
  • Page 65: Install The Battery

    Figure 4-31. Ensure the guides are secure underneath the shelf supports 3. Ensure that the shelf snaps into place and then close the printer lid. Install the Battery Once the G4 console with eBox is installed on the OmniRx, the battery must be installed and connected. © 2011 Omnicell, Inc.
  • Page 66 4-20 OmniRx G4 Console Upgrade Add the G4 Console 1. Remove the three screws that secure the eBox lid to the eBox. Figure 4-32. Remove the screws that secure the ebox lid 2. Remove the eBox lid by sliding it toward the side of the eBox with the USB ports then lift.
  • Page 67 OmniRx G4 Console Upgrade 4-21 Add the G4 Console 4. Connect the battery to J2 on the PowerCom4 board. Figure 4-34. Connect the battery cable to the PowerCom4 board 5. Check the other connections on the PowerCom4 board to ensure they have not come loose.
  • Page 68: Replace The G4 Omnirx Lid

    8. Replace the three screws that were previously removed to secure the lid to the eBox. Replace the G4 OmniRx Lid Once the G4 console and the eBox are successfully installed, the OmniRx lid needs to be installed. OmniRx Service Guide/67-2023 Rev F...
  • Page 69 OmniRx G4 Console Upgrade 4-23 Add the G4 Console 1. Lift the OmniRx lid onto the back of the machine and set the lid down, ensuring that it rests on the console frame pegs. Figure 4-36. Place the lid onto the pegs on the frame of the OmniRx Figure 4-37.
  • Page 70 4-24 OmniRx G4 Console Upgrade Add the G4 Console 2. Set the lid down gently and use the #2378 cam lock key to lock the lid. Figure 4-38. Close and lock the lid 3. Plug the OmniRx into a medical-grade power outlet and power on the system.
  • Page 71: Omnirx G4 Service Guide

    OmniRX G4 Service Guide Introduction This section will describe how to remove and replace the FRU-level parts in an OmniRx with G4 components installed, including the E-Box, the monitor, the keyboard and the printers. Remove the OmniRx Lid 1. Perform a graceful shutdown of the OmniRx.
  • Page 72 5-2 OmniRX G4 Service Guide Introduction 3. Lift the lid up. Do not let go of the lid as it lifts. Important: Do not let go of the lid as it lifts. It is not attached to the OmniRx and will fall if it is released after it is lifted up from the backside of the OmniRx.
  • Page 73: Remove The Keyboard

    Introduction Remove the Keyboard 1. Remove the two screws on the under side of the OmniRx G4 console that secure the keyboard. Figure 5-3. Remove the bottom two keyboard screws 2. Remove the cosmetic cover on the front of the keyboard tray.
  • Page 74 3. Remove the four screws on the keyboard tray that secure the keyboard to the console. Figure 5-5. Remove the top four screws that secure the keyboard 4. Lift and remove the keyboard from the G4 console. Set the keyboard aside. Figure 5-6. Lift and remove the keyboard OmniRx Service Guide/67-2023 Rev F ©...
  • Page 75 OmniRX G4 Service Guide 5-5 Introduction 5. Remove the nut that secures the keyboard ground cable. Figure 5-7. Remove the keyboard ground cable nut 6. Remove the ground cable. 7. Disconnect the Fingerprint scanner USB cable (if present) and the keyboard cable from the side of the E-Box.
  • Page 76: Remove The Monitor

    1. Remove the four nuts that secure the monitor to the OmniRx frame. Use a 5mm nut driver. Figure 5-8. Remove the nuts that secure the monitor to the OmniRx G4 console 2. Lift the monitor stand from the front two screw pegs first, ensuring that the monitor clears the screw pegs.
  • Page 77: Remove The E-Box

    OmniRX G4 Service Guide 5-7 Introduction 3. Reach down and lift the monitor up from the base and move it back toward the back of the OmniRx. Figure 5-10. Align the monitor stand 4. Lift the AIO up and out of the OmniRx.
  • Page 78 5-8 OmniRX G4 Service Guide Introduction 2. Disconnect any power cables from the E-Box. Figure 5-11. Disconnect any power cables from the E-Box. 3. Disconnect the wireway cable from the E-Box. Figure 5-12. Disconnect the wireway cable OmniRx Service Guide/67-2023 Rev F...
  • Page 79 OmniRX G4 Service Guide 5-9 Introduction 4. Loosen the two screws on the right-hand side of the E-Box that secure the E-Box to the OmniRx frame. Figure 5-13. Loosen the screws that secure the E-Box t the OmniRx frame 5. Loosen the two screws securing the bracket on the left-hand side of the E-Box.
  • Page 80: Remove The Printer Bay

    5-10 OmniRX G4 Service Guide Introduction 6. Slide the E-Box back toward the rear of the OmniRx to free the brackets from the bolts. Figure 5-15. Slide the E-Box back 7. Lift the E-Box and remove it from the OmniRx.
  • Page 81 OmniRX G4 Service Guide 5-11 Introduction 2. Pull the platen lever up and pull the receipt paper from the printer. Figure 5-16. Open the platen level 3. Remove the paper from its holder. Figure 5-17. Remove the receipt printer paper ©...
  • Page 82: Remove The Omnirx Sled

    5-12 OmniRX G4 Service Guide Introduction 4. Remove the paper tray from the OmniRx. Figure 5-18. Remove the paper tray Remove the OmniRx Sled 1. Remove the screw in the printer bay that secures the OmniRx sled to the frame.
  • Page 83 OmniRX G4 Service Guide 5-13 Introduction 2. Remove the two screws that secure the sled to the OmniRx frame on the back of the sled. Figure 5-20. Remove the screw on the right rear side of the sled Figure 5-21. Remove the screw on the left rear side of the sled ©...
  • Page 84 5-14 OmniRX G4 Service Guide Introduction 3. Remove the screw located behind the printer bay that secures the sled to the Rx frame. Figure 5-22. Remove the screw that secures the Rx sled to the frame 4. Lift the OmniRx sled up and remove it from the frame.
  • Page 85: Set The G4 Sled On The Omnirx Frame

    Introduction Set the G4 Sled on the OmniRx Frame 1. Lift the G4 console onto the OmniRx frame. Ensure that the wireway cable is laid over the edge of the frame and available. Figure 5-23. Place the G4 console on the OmniRx with the wireway calbe free 2.
  • Page 86 3. Bring the wireway cable out through the back of the G4 console. Figure 5-25. Bring the wireway cable through the back 4. Organize the wires on the G4 console so that they are clear of the surface area where the E-Box will be placed. Use the clips provided.
  • Page 87 OmniRX G4 Service Guide 5-17 Introduction 5. Replace the screw in the printer bay that secures the OmniRx sled to the frame. Figure 5-27. Replace the screw that secures the sled to the Rx frame © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 88 5-18 OmniRX G4 Service Guide Introduction 6. Replace the two screws that secure the sled to the OmniRx frame on the back of the sled. Figure 5-28. Replace the screw on the right rear side of the sled Figure 5-29. Replace the screw on the left rear side of the sled OmniRx Service Guide/67-2023 Rev F ©...
  • Page 89 OmniRX G4 Service Guide 5-19 Introduction 7. Replace the screw located behind the printer bay that secures the sled to the Rx frame. Figure 5-30. Replace the screw that secures the Rx sled to the frame © 2011 Omnicell, Inc.
  • Page 90: Replace The Components Od The Omnirx Sled

    Install the Touch-Screen Monitor Install the Monitor 1. Set the monitor in place in the G4 Console. Ensure that the monitor clears the locking mechanism and sets down with all four protruding screws fitting through the respective holes in the stand.
  • Page 91 OmniRX G4 Service Guide 5-21 Install the Touch-Screen Monitor Figure 5-32. Place the monitor stand 2. Secure the monitor using the four nuts provided. Figure 5-33. Secure the monitor to the OmniRx G4 console © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 92: Replace The Keyboard

    Install the Touch-Screen Monitor Replace the Keyboard 1. Feed the USB and power cables through the rear opening in the G4 console frame. Figure 5-34. 2. Replace the ground cable and secure it with the nut that was previously removed.
  • Page 93 OmniRX G4 Service Guide 5-23 Install the Touch-Screen Monitor 3. Set the keyboard back into place and secure the top four screws that had previously been replaced. Figure 5-36. 4. Replace the cosmetic cover. Figure 5-37. Replace the cosmetic cover ©...
  • Page 94: Replace The E-Box

    Figure 5-38. Replace the two screws Replace the E-Box Prepare the E-Box Before the E-Box can be placed into the G4 console, brackets need to be added and a wireway cable adapter plate needs to be included with the box. OmniRx Service Guide/67-2023 Rev F...
  • Page 95 OmniRX G4 Service Guide 5-25 Replace the E-Box 1. Add the wireway adapter card to the E-Box. Figure 5-39. Add the wireway adapter card 2. Add a bracket to the front and rear side of the E-Box that contains the wireway adapter card.
  • Page 96 5-26 OmniRX G4 Service Guide Replace the E-Box 3. Add a bracket to the side of the E-Box that contains the USB ports and the keyboard connectors. Figure 5-41. Add the second bracket to the E-Box 4. Add the external ERB cable connector to the second bracket.
  • Page 97: Add The E-Box

    OmniRX G4 Service Guide 5-27 Replace the E-Box Add the E-Box 1. Place the two nuts onto the screw threads at the front of the E-Box enclosure area. Important: Do not tighten the nuts yet Figure 5-43. Place the two nuts Figure 5-44.
  • Page 98 5-28 OmniRX G4 Service Guide Replace the E-Box 2. Set the E-Box onto the G4 console. Ensure that the brackets slide into place around the support screws. Figure 5-45. Set the E-Box in place Figure 5-46. Ensure the Box is lined up 3.
  • Page 99 OmniRX G4 Service Guide 5-29 Replace the E-Box 4. Connect the wireway cable. The cable is notched, so it will only fit into the adapter one way. do not force the cable as it may damage the adapter. Figure 5-47. Connect the wireway cable 5.
  • Page 100 5-30 OmniRX G4 Service Guide Replace the E-Box 6. Connect the two power cables. It does not matter which cable goes into which molex connector. Figure 5-49. Connect the Power Cables 7. On the other side of the E-Box, connect the video cable and the data cable.
  • Page 101 OmniRX G4 Service Guide 5-31 Replace the E-Box 8. Connect the audio cable. Figure 5-51. Connect the audio cable 9. Connect the four USB cables to the ports on the side of the E-Box. It does not matter where each USB cable is plugged in.
  • Page 102: Replace The Omnirx Lid

    10. Connect one end of the peripheral extension cable to the E-Box and the other end to the strain relief connector. Figure 5-53. Connect the peripheral extension cable Replace the OmniRx Lid Once the G4 console and the E-Box are successfully installed, the OmniRx lid needs to be installed. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 103 OmniRX G4 Service Guide 5-33 Replace the E-Box 1. Lift the OmniRx lid onto the back of the machine and set the lid down, ensuring that it rests on the console frame pegs. Figure 5-54. Place the lid on the pegs Figure 5-55.
  • Page 104 5-34 OmniRX G4 Service Guide Replace the E-Box 2. Set the lid down gently and use key # (insert key # here) to lock the lid. Figure 5-56. Lock the lid 3. Power up the OmniRx. OmniRx Service Guide/67-2023 Rev F...
  • Page 105: Ct Pc E-Box

    CT PC E-Box 6-1 Introduction CT PC E-Box Introduction This procedure will guide the user through the procedures required to remove a G4 E-Box and replace any FRU parts within the E-Box. Tools Required  Torx T10 driver  Torx T15 driver ...
  • Page 106 6-2 CT PC E-Box Open the E-Box 3. Set the lid and the three screws aside. Figure 6-2. The CTPC console E-Box with the lid removed OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 107: Remove/Replace The Hard Drive

    Remove/Replace the Hard Drive Remove the Hard Drive 1. Remove the data and power cables from the hard drive. Figure 6-3. Disconnect the data and power cables from the hard drive © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 108 Figure 6-4. Loosen the screw that secures the hard drive to the E-Box wall 3. Lift the hard drive up, pull it away from the drive all, and remove it from the E-Box. Figure 6-5. Remove the hard drive OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 109: Replace The Hard Drive

    Figure 6-6. Replace the hard drive 2. Tighten the screw that connects the hard drive plate to the E-Box wall. Figure 6-7. Tighten the screw that secures the hard drive to the E-Box wall © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 110 6-6 CT PC E-Box Remove/Replace the Hard Drive 3. Replace the data and power cables to the hard drive. Figure 6-8. Connect the data and power cables for the hard drive OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 111: Remove/Replace The Fans

    Remove/Replace the Fans Remove/Replace the Fans Remove the Fans 1. Remove the four screws that secure each cooling fan to the E-Box. Figure 6-9. Remove the screws securing the fans to the E-Box © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 112: Replace The Fans

    2. Disconnect the fan cables from the PowerCom4 board. Figure 6-10. Disconnect the fan cables from the PowerCom4 board 3. Remove the fans from the E-Box. Replace the Fans 1. Hold each fan in place inside the E-Box. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 113 2. Replace the four screws that secure each cooling fan to the E-Box. Figure 6-11. Replace the screws securing the fans to the E-Box 3. Connect the fan cables to the PowerCom4 board. Figure 6-12. Connect the fan cables to the PowerCom4 board © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 114: Remove/Replace The Battery

    2. Disconnect the cable that connects the battery to the PowerCom4 board. Figure 6-14. Disconnect the cable that connects the battery to the PowerCom4 board 3. Remove the battery from the E-Box. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 115: Replace The Battery

    Figure 6-15. Set the battery on the straps and secure the straps 3. Connect the cable that connects the battery to the PowerCom4 board. Figure 6-16. Connect the battery cable to the PowerCom4 board © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 116: Remove/Replace The Power Supply

    Remove/Replace the Power Supply Remove the Power Supply 1. Disconnect the cable that connects the power supply to the PowerCom4 board. Figure 6-17. Disconnect the power supply cable from the PowerCom4 board. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 117 Figure 6-18. Remove the screw that secures the power supply to the E-Box 3. Pull the power supply away from the E-Box wall. 4. Lift, but do not remove, the power supply from the E-Box. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 118 Figure 6-19. Figure 1-19. Power supply power cable 5. Remove the power cable connected to the power supply. Figure 6-20. Disconnect the power cable from the power supply 6. Remove the power supply from the E-Box. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 119: Replace The Power Supply

    Replace the Power Supply 1. Place the power supply into the opening in the E-Box. Figure 6-21. Place the power supply 2. Reconnect the power cable to the power supply. Figure 6-22. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 120 4. Secure the power supply to the E-Box by replacing the screw that secures the power supply to the E-Box. Figure 6-24. Replace the screw that secures the power supply to the E-Box OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 121: Remove The Wireless Card

    Figure 6-25. Connect the power supply power cable to the PowerCom4 board Remove the wireless card 1. Remove the screw that secures the wireless card to the E-Box frame. Figure 6-26. Remove the screw securing the wireless card to the E-Box © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 122: Replace The Wireless Card

    Figure 6-27. Remove the wireless card from the E-Box Replace the wireless card 1. Place the wireless card into the E-Box, ensuring that it fits snugly into the slot on the motherboard. Figure 6-28. Replace the wireless card OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 123: Remove/Replace The Power Entry Module

    Remove the Power Entry Module 1. Remove the battery. Follow the steps in “Remove the Battery” on page 1-8. 2. Remove the power supply. Follow the steps in “Remove the Power Supply” on page 1-10. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 124: Replace The Power Entry Module

    1. Feed the cables through the back of the E-Box into the box. 2. Pinch the tabs on the corners of the power entry module and push the module from the rear into the box. OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 125 Figure 6-31. Replace the screws that secure the ground wires to the E-Box 4. Replace the power supply. Follow the steps in “Replace the Power Supply” on page 1-13. 5. Replace the battery. Follow the steps in “Replace the Battery” on page 1-9. © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 126 6-22 CT PC E-Box Remove/Replace the Power Entry Module OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 127: Appendix A: Part List

    MODEL OMD4,4-BIN MATRIX DRAWER,UNLIT Matrix Drawer bin labels [comes with drawer] Matrix Drawers Labels 15-7020 false drawer front MFG,ASSY,DRAWER,FRONT,DUMMY RX2 Pharmacy Drawer Installation Table A-1. OmniRx Part List © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 128 Manual Override Cable Service 53-1082 keyboard cover BKT,COVER,KEYBD,OMNIRX PS/2 Keyboard LCD Screen 53-1105 LCD bezel BEZEL, NEC LVDS LCD DISPLAY Removal 53-2078 wireway WIREWAY,OMNIRX Wireway Removal Table A-1. OmniRx Part List OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 129 Installation 80-0802 speaker cable CONN,CABLE ASSY,MOLDED PLUG,3.5MM STEREO,SHL'D,PVC,36IN Speaker Removal 82-6061 jumper JUMPER,SHUNT,0.1",15AU,RED Standardization Changes 91-7040 drawer slide SLIDE,OUTER HALF, DRAWER,RX,ACCURIDE C3834-156-1 [right side] Wireway Removal Table A-1. OmniRx Part List © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 130 Cable Service PowerCom2 Tray 94-6170 (electronics sled) fastener STUD,1/4,TURN,WING,HD,SOUTHCO 94-6173 (PC card) screw SCREW,SHCS,4-40,X,3/16,SS Seiko Printer APS Printer 95-6015 paper PAPER,THERMAL,92M ROLL,80MM WIDE Seiko Printer APS Printer Table A-1. OmniRx Part List OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 131 2-1 keyboard 1-10 labels 3-4 LAN cable 1-14, 4-2 LCD screen 1-2 locking lid drawers 3-1 manual override assembly 2-6 manual override cable 2-4 manual override cover 2-1, 3-5, 3-8 © 2011 Omnicell, Inc. OmniRx Service Guide/67-2023 Rev F...
  • Page 132: In-2 Index

    IN-2 Index OmniRx Service Guide/67-2023 Rev F © 2011 Omnicell, Inc.
  • Page 133: Documentation Feedback

    Documentation Feedback This document is designed to provide relevant technical information to those responsible for the implementation, service, and support of Omnicell products. The Documentation team needs your input, so we can continue to improve our publications. Sending Comments to the Technical Documentation Team Did this document meet your needs? If so, please let us know what we’re doing right.

Table of Contents