Dimplex DuoHeat Radiator
Models: Duo300i, Duo400i and Duo500i
Dimensions
(including clearances diagram)
(millimetres)
Models
Specification
300i
1.3kW / 0.28kW
400i
1.95kW / 0.34kW
500i
2.6kW / 0.39kW
Height
Width
Model
A
B
Duo300i
712mm
600mm
Duo400i
712mm
830mm
Duo500i
712mm
1060mm
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
These instructions should not be left with the user, as this would invite the dismantling and servicing by unqualified persons.
There is a separate instruction leaflet which should be left with the user explaining how the radiator should be operated.
TO ENSURE THIS APPLIANCE IS OPERATING CORRECTLY, IT IS ESSENTIAL TO PERFORM THE CHECK PROCEDURE DETAILED
ON THE BACK PAGE OF THIS INSTRUCTION. THIS MUST BE COMPLETED BEFORE NORMAL OPERATION COMMENCES.
IMPORTANT SAFETY ADVICE
WARNING - This radiator is VERY HEAVY. In order to maintain stability and to ensure its future safety in use, it is essential
that the radiator is FIXED SOUNDLY TO A WALL and that the feet are mounted on a FIRM, LEVEL SURFACE. Care should
be taken to avoid irregular surfaces, such as may result from tiled surrounds partially protruding under the radiator. It is
important that the following instructions are strictly followed.
WARNING – It is important that the fixing device chosen is appropriate to the wall material to which the radiator is being
fixed. Some modern internal building materials are very low density block and require specialised fixing devices to
provide a safe, secure installation.
WARNING – If during any reassembly of the radiator, a part of the thermal insulation shows damage or deterioration which
may impair safety, it should be replaced with an identical part.
WARNING – This radiator must not be located below a fixed socket outlet.
Suggested Wall Fittings (see page 7 for further information)
Solid brick/block: No. 10 Rawlplug fibre inserts (provided). 5.5mm drill bit. Drill 8mm deeper than rawlplug length.
Plasterboard: If possible locate studding and use No. 10 woodscrews directly into the wood, otherwise M5 intersets.
For other wall types seek specialist advice.
DO NOT COVER OR OBSTRUCT the surfaces of the appliance.
DO NOT POSITION under windows where curtains may contact the radiator (see minimum clearances above).
DO NOT PLACE OBJECTS in contact with the radiator.
Depth
C
130mm+10mm
130mm+10mm
130mm+10mm
NOTE ALSO THE INFORMATION GIVEN ON THE APPLIANCE
Curtains
B
75mm
min.
75mm
min.
- 1 -
Installation Instructions
85702
Shelf or Overhang
250mm
min.
150mm
min.
A
Furniture
or other
obstruction
110mm
Issue 8
C

Advertisement

loading
Need help?

Need help?

Do you have a question about the Duo300i and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Creda Duo300i

  • Page 1 Installation Instructions 85702 Issue 8 Dimplex DuoHeat Radiator Models: Duo300i, Duo400i and Duo500i Dimensions (including clearances diagram) Shelf or Overhang Curtains (millimetres) Models Specification 250mm 300i 1.3kW / 0.28kW min. 75mm 400i 1.95kW / 0.34kW min. 500i 2.6kW / 0.39kW...
  • Page 2: Electrical Connection

    LIVE BLACK (direct acting supply only):CONTROL WIRE Energy Retention Cells Energy retention cells are supplied separately to the radiator in packs of two. The reference number is 85743. Duo300i Duo400i Duo500i 8 Cells (4 Packs) 12 Cells (6 Packs) 16 Cells (8 Packs)
  • Page 3: Circuit Diagram

    Circuit Diagram - 3 -...
  • Page 4: Installation Of The Radiator

    INSTALLATION OF THE RADIATOR ASSEMBLY Turn the carton upside down and open the carton from the bottom. Remove the feet from the polystyrene IMPORTANT corner supports and the accessories bag from the polystyrene centre support. BOTH FEET MUST BE SECURELY ATTACHED TO THE BOTTOM OF THE RADIATOR BEFORE IT IS REMOVED FROM THE CARTON, AVOIDING...
  • Page 5 Stand the radiator on its feet and remove packaging Swing bottom of panel slightly away from the rest of by sliding over the top of the radiator. Remove all the radiator (Fig. 7 ) and lift upwards to unhook the additional internal protective packaging.
  • Page 6: Wall Mounting

    WALL MOUNTING The following must be applied before fixing the radiator to the wall: NO SKIRTING BOARD / SKIRTING BOARD NO TALLER THAN 100MM The radiator is to be mounted as shown in Fig. 11 with the wall spacer bracket in its standard orientation. Mark the position of the two mounting slots with the radiator pushed tight against the wall Fig.
  • Page 7 SKIRTING BOARD TALLER THAN 100MM Use the 10mm and 30mm spacers provided (2 x 10mm and 2 x 30mm) If the skirting board is taller than 100mm, the radiator is to be mounted as shown in fig 12 . Remove the wall mounting bracket and reassemble in the IMPORTANT: UNDER NO alternative orientation to give a greater spacing...
  • Page 8 Remove the inner front panel by removing the screws along its top edge Fig. 13 . Carefully lift the bottom of the front inner panel out of the retaining flange at the base of the radiator, Fig 13 and remove the internal packaging, Fig.
  • Page 9 Carefully fit the bottom row of the back layer of energy retention cells, placing the two end cells in position first with the flat side toward the back. Fit the top row of cells also with the recess toward the element. Refit the elements by carefully feeding the tails down through the hole in the base insulation, ensuring the tab is pointing forward.
  • Page 10 RADIANT ELEMENT OVERRIDE In its factory default setting, the radiant element will be allowed to operate for up to 2 hours after the beginning of the off peak charge period to maintain a comfortable room temperature if required. After 2 hours the radiant element will be automatically disabled until the end of the off peak charge period.
  • Page 11 ELECTRICAL CONNECTION IMPORTANT The wires in the direct acting supply cable are coloured in EPLACING MAINS WIRE ON DIRECT ACTING SUPPLY CIRCUIT . T85) accordance with the following code: ESISTING ABLE Follow the procedure to remove the outer front. Remove the PCB Bracket from the bottom of the outer front. GREEN &...
  • Page 12 CHECK PROCEDURE FOR INSTALLERS FOLLOWING INSTALLATION THIS CHECK PROCEDURE SHOULD BE CARRIED OUR BY A COMPETENT INSTALLER ONLY. A QUICK START GUIDE AND OPERATING INSTRUCTIONS ARE AVAILABLE FOR END USERS. DuoHeat has two heat output modes Comfort (Radiant Heat) To check the radiant panel operation (comfort heat). and Background (Retained Heat) .