Parameters; Technical Parameters - Ebyte NB144E User Manual

Four serial ports serial server
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd.

3 Parameters

3.1 Technical parameters

project
power supply
Network port
serial port
Operating mode
Network protocol
IP acquisition method
DNS
configuration method
IP address
local port
subnet mask
gateway
Serial cache
Serial
packaging
mechanism
Serial baud rate
data bit
stop bit
Check Digit
installation method
Product Size
product weight
Working temperature
and humidity
storage
temperature
and humidity
Copyright ©2012,Chengdu Ebyte Electronic Technology Co., Ltd.
interface
illustrate
Crimp terminal
DC 8~28 Power supply, used when not available;
Crimp terminal: 5.08 mm Phoenix terminal;
D C female
D C female head: straight plug-in round hole, outer diameter
5.5mm , inner diameter 2.0 mm ;
RJ45
10M
Interface 1 ( RS485 , 3.81mm Phoenix terminal, support isolation);
Channel
1
to
Interface 2 ( RS232 , standard RS232 line sequence D B9 female);
Channel 4
Interface 3 ( RS 422 , 3.81mm Phoenix terminal, support isolation);
TCP Server (default), TCP Client, UDP Server, UDP Client, HTTP Client , MQTT Client
TCP/IP, UDP, MQTT , HTTP , IPv4, I CMP , APR , D HCP , D NS
DHCP, static IP (default)
Support, address can be configured
Parameter configuration host computer , AT command
192.168.3.7 (customizable)
Channel 1~ 4 : 8 001-800 4 (can be customized)
255.255.255.0 (customizable)
192.168.3.1 (customizable)
512 Bytes
512 Bytes
2400 ~ 115200 bps (default 115200)
8
1 (default), 2
None (default), Odd, Even
positioning hole
1 98 x 108x26.5mm ( LxWxH ) _ _
5 30 g ± 5 g
-40 ~ +85℃, 5% ~ 95%RH (no condensation)
-40 ~ +105℃, 5% ~ 95%RH (no condensation)
NB144E User Manual
10

Advertisement

Table of Contents
loading