Unit Assembly Prior To Installation; Venting Introduction - UltraGlow G36D Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

Top Header
10" dia. hole
through wall
1/2"
Drywall
or for DuraVent
2"
3-1/2"
4"
17-1/8"
Opening for gas
connection
Note: 40-1/2" (1029mm) is the minimum
height for both fl ex termination or
Simpson Dura-Vent venting.
5) The unit does not have to be completely
enclosed in a chase. The clearance on
top of the unit is 0" to the standoffs so
combustible building materials can be
laid directly on top of the standoffs. You
must maintain clearance from the vent to
combustible materials for fl ex, see section
"Clearances."
6) Use steel studs for framing where the
1-1/2" (38mm) clearance from the vent to
combustible material cannot be maintained,
e.g. front top header.
UNIT ASSEMBLY
PRIOR TO
INSTALLATION
The Top Facing Support, the Side Nailing Strips
and the 2 Top Standoffs must be correctly
positioned and attached to the top before unit
is slipped into position.
Top Standoff Assembly
The top standoffs are shipped in a fl at position
and must be folded into shape and attached.
1) Remove the standoffs from the fi replace
top.
2) Take each standoff and bend into the correct
shape. Bend up at the bend lines until the
screw holes in the standoff and the pre-
punched screw holes on the fi replace top
line up.
UltraGlow
G36D Zero Clearance Direct Vent Gas Fireplace
®
3) Attach the standoff securely to the top
with 2 screws per standoff (on opposite
corners).
for Flex
Top Facing Support and
Side Nailing Strips
Determine the total thickness of facing material
(e.g. drywall plus ceramic tiles) to allow the
fi nished surface to be fl ush with the front of the
unit. Total facing thickness can vary from 1/2"
(13mm) to 1-1/4" (32mm) thick.
The Top Facing Support & Side Nailing Strips can
be mounted in 3 different positions depending
on the thickness of the facing material.
Screw
Screw
Position
Position
A
A
B
B
C*
* For "C" screw position the top facing support
is reversed.
1) Mount Top Facing Support using the 3
supplied screws into the three pre-punched
screw holes on the top front of the unit. Use
hole positions A, B, or C depending on your
facing depth.
Facing Material
Facing Material
Depth
Depth
1/2"
1/2"
/ 13mm
/ 13mm
7/8"
7/8"
/ 22mm
/ 22mm
1-1/4"
1-1/4"
/ 32mm
/ 32mm
INSTALLATION
"C" Screw Position:
For a facing material depth of 1-1/4"
(32mm), the top facing support must be
reversed.
2) Use the same screw hole position for the
Side Nailing Strips as was used for the Top
Facing Support. Attach each side nailing
strip using 3 screws.
VENTING
INTRODUCTION
The G36D uses the "balanced fl ue" technology
Co-Axial system. The inner liner vents products
of combustion to the outside while the outer liner
draws outside combustion air into the combustion
chamber thereby eliminating the need to use
heated room air for combustion and losing warm
room air up the chimney.
Note:
These flue pipes must not be
connected to any other appliance.
The gas appliance and vent system must be
vented directly to the outside of the building,
and never be attached to a chimney serving a
separate solid fuel or gas burning appliance.
Each direct vent gas appliance must use it's own
separate vent system. Common vent systems
are prohibited.
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

G36d-ng1G36d-lp1

Table of Contents