Operating Instructions; Operating; Instructions; Lighting Procedure - UltraGlow G36D Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
5) Verify that the venting and cap are
unobstructed.
6) Ensure that the brick panels are installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8) The unit should never be turned off, and on
again without a minimum of a 60 second
wait.
LIGHTING
PROCEDURE
IMPORTANT
To ignite or reignite the pilot,
you must fi rst release the ten-
sion springs below the door.
Only when the pilot holds, without pressure
being applied to the control knob, reapply the
tension springs to the door. The unit must
not
not be operated with the tension springs
not be operated with the tension springs
unattached.
IMPORTANT Gas cock knob cannot be turned
from "PILOT" to "OFF" unless it is partially
depressed.
1) Turn burner OFF using "ON/OFF" switch.
34
2) Turn gas control knob so indicator points
to "OFF" position and allow 5 minutes for
any gas in the combustion chamber to
escape.
3) Turn gas control knob counterclockwise
so indicator points to the "PILOT" position.
Depress the gas control knob fully. Depress
the igniter button several times until the
pilot lights. After approximately one minute,
release the gas control knob. The pilot fl ame
should continue to burn. If the pilot does
not remain lit, repeat operation allowing a
longer period before releasing gas control
knob.
4) When the pilot stays lit, turn the gas knob
further counterclockwise to the "ON"
position.
5) Use the wall switch, thermostat or remote
control to turn on the unit.
6) Rotate the fl ame height regulator to adjust
the fl ame height higher or lower.
SHUTDOWN
PROCEDURE
1) Use the wall switch, thermostat or remote
control to turn off the main burner.
2) Turn the main gas control clockwise to the
"OFF" position to turn off the pilot.
3) Turn off all electric power to appliance if
service is to be performed.

FIRST FIRE

The fi rst fi re in your fi replace is part of the
paint curing process. To ensure that the paint
is properly cured, it is recommended that you
burn your fi replace for at least four (4) hours
the fi rst time before you use it with the fan on.
When fi rst operated, the unit will release
an odour caused by the curing of the paint,
the burning off of any oils remaining from
manufacturing. Smoke detectors in the house
may go off at this time. Open a few windows to
ventilate the room for a couple of hours.
The glass panel may require cleaning after the
DO NOT ATTEMPT
unit has cooled down.
TO CLEAN THE GLASS WHILE IT
IS HOT.
Note: When the glass is cold and the
appliance is lit, it may cause
condensation and fog the glass.
This condensation is normal and
will disappear in a few minutes as
the glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
During the fi rst few fi res, a white fi lm
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the fi lm will bake on and
become very diffi cult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
AERATION
ADJUSTMENT
The air shutter can be adjusted by moving the
adjusting wire up or down. The wire is accessed
through the bottom louver opening. Open the air
shutter for a blue fl ame or close for a yellower
fl ame. The burner aeration is factory set but
may need adjusting due to either the local gas
supply or altitude.
Minimum Air Shutter Opening:
3/16"
1/2"
CAUTION: Carbon will be produced if air shutter
is closed too much.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
Note: Aeration Adjustment should only
be performed by an authorized
Regency
installation or service.
Adjustment Wire: push to close or
pull to open aeration cap.
Closed - Tall yellow
Open - Short Blue
UltraGlow
G36D Zero Clearance Direct Vent Gas Fireplace
G36D Zero Clearance Direct Vent Gas Fireplace
®
®
®
glass should
Natural Gas
Propane
Installer at the time of
Installer at the time of
®
®
®

Advertisement