Rigid Pipe Venting Systems; Horizontal Or Vertical Terminations - UltraGlow G36D Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

The minimum components required for a basic horizontal termination
are:
1
Horizontal Termination Cap
1
90
Elbow
o
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of pipe to suit wall thickness (see chart)
Wall thickness is measured from the back standoffs to the inside mounting
surface of termination cap. For siding other than vinyl furring strips may
be used, instead of the vinyl siding standoff, to create a level surface to
mount the vent terminal. The Terminal must not be recessed into siding.
Measure the wall thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding),
measure to outside surface of wall without siding and add 2 inches.
Vertical
Terminal
Storm Collar
(Part # 953)
Flashing
943 or 943S
Ceiling Firestop
(Part # 963)
Pipe Length
The FPI AstroCap
and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent GS,
TM
American Metal Products Ameri Vent Direct Vent and Selkirk Direct-Temp. AstroCap
Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
UltraGlow
G36D Zero Clearance Direct Vent Gas Fireplace
®

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

Vinyl Siding
Standoff (Optional)
(Part #950)
Adj.Pipe Length
11" - 14-5/8"
90 Elbow
o
24" Pipe
Length
Rigid Pipe Adaptor
(Part# 510-994)
When using Rigid Vent piping other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
Wall Thickness
(inches)
4" - 5-1/2"
7" - 8-1/2"
10" - 1-1/2"
9" - 14-1/2"
15" - 23-1/2"
Wall Thickness
(inches)
3-1/4" - 6-3/4"
7-3/4" - 16-1/4"
7-1/4" - 8-3/4"
4-1/4" - 5-3/4"
Horizontal
Termination Cap
(Part# 946-523/P)
Wall Thimble
(Part # 942)
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
Riser is acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Dura-Vent Direct Vent GS, Selkirk Direct-
Temp, Ameri Vent Direct venting and Security
Secure Vent systems. Use of these systems with
the Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.
is the proprietary trademark of FPI Fireplace Products International
TM
INSTALLATION
Flat Wall Installation
Vent Length Required
(inches)
6"
9"
12"
11" - 14-5/8" Adj. Pipe
17" - 24" Adj.
Corner Installation
Vent Length Required
(inches)
11" - 14-5/8" Adj. Pipe
17" - 24" Adj. Pipe
6" + 12"
9" + 9"
6" + 9"
Alternate
Horizontal Ter-
mination Caps
TM
and FPI
13