WARNING: If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage, personal injury
or loss of life.
FOR YOUR SAFETY:
vapors and liquids in the vicinity of this or any other appliance. Installation
and service must be performed by a qualifi ed installer, service agency or
the gas supplier.
This appliance may be installed in an aftermarket, permanently located,
manufactured home (USA only) or mobile home, where not prohibited by
local codes. This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with other gases,
unless a certifi ed kit is used.
Tested by:
918-515
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
MODELS:
G36D-NG1 Natural Gas
Do not store or use gasoline or other fl ammable
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.regency-fi re.com
G36D-LP1 Propane
Owners &
Installation Manual
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance.
Do not touch any electrical switch:
Do not touch any electrical switch:
Do not touch any electrical switch:
Do not touch any electrical switch:
do not use any phone in your building
Immediately call your gas supplier
Immediately call your gas supplier
Immediately call your gas supplier
Immediately call your gas supplier
from a neighbour's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier,
If you cannot reach your gas supplier,
If you cannot reach your gas supplier,
If you cannot reach your gas supplier,
call the fi re department.
12/18/05

Advertisement

Table of Contents
loading

Summary of Contents for UltraGlow G36D

  • Page 1 Owners & G36D Zero Clearance Direct Vent Gas Fireplace Installation Manual MODELS: G36D-NG1 Natural Gas G36D-LP1 Propane WARNING: If the information in these instructions are not followed exactly, FOR YOUR SAFETY a fi re or explosion may result causing property damage, personal injury What to do if you smell gas: or loss of life.
  • Page 2 fi replace at the fl ick of a switch. The model G36D has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
  • Page 3: Table Of Contents

    Installing Valve .............37 Venting ................ 11 G36D Main Assembly ..........38 Rigid Pipe Venting Components List ......12 G36D Burner Assembly & Log Set ......39 Rigid Pipe Venting Systems ........13 G36D Flush Front Assembly ........40 Horizontal or Vertical Terminations ......13 Rigid Pipe Venting Arrangements WARRANTY - Horizontal Terminations ..........14...
  • Page 4: Safety Label

    SAFETY LABEL This is a copy of the label that accompanies each G36D Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open.
  • Page 5: Installation

    Make it a practice to have all of your gas THEY ARE IN THE SAME ROOM AS appliances checked annually. THE APPLIANCE. 13) Do not slam shut or strike the glass door. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 6: G36D Unit Dimensions

    4) The G36D Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C, D. See Diagram...
  • Page 7: Clearances

    See the "Unit Aseembly Prior to Installation" section for assembly details. The HeatWave Duct Kit has different clearance and framing requirements, check the requirements, check the HeatWave manual for details. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 8: Combustible Mantels

    Mantel can be installed anywhere in shaded area or higher using the above scale. Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 9: Unit Assembly Prior To Installation

    1-1/4" / 32mm / 32mm PRIOR TO The G36D uses the "balanced fl ue" technology INSTALLATION Co-Axial system. The inner liner vents products * For "C" screw position the top facing support of combustion to the outside while the outer liner is reversed.
  • Page 10: Exterior Vent Termination Locations

    INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 11: Venting

    Horizontal Terminations Only These venting systems, in combination with the G36D Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent Termination Locations"...
  • Page 12: Rigid Pipe Venting Components List

    Rigid Pipe Adaptor (Must use with all Rigid Piping) 946-523/P AstroCap Horizontal Cap 640-530/P Riser Vent Terminal 946-206 Vinyl Siding Standoff - AstroCap UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 13: Rigid Pipe Venting Systems

    American Metal Products Ameri Vent Direct Vent and Selkirk Direct-Temp. AstroCap is the proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 14: Rigid Pipe Venting Arrangements - Horizontal Terminations

    Horizontal vent must be supported every 3 feet. • Firestops are required at each fl oor level and whenever passing through a wall. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ®...
  • Page 15 Maintain clearances to combustibles as listed in the "Clearances," "Locating Your Gas Stoves," "Combustible Mantels," "Framing and Finishing," & "Hearth Requirement" sections. • Horizontal vent must be supported every 3 feet. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 16: Rigid Pipe Venting Arrangements - Vertical Terminations

    INSTALLATION RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS (Propane & Natural Gas) The G36D is approved for a maximum 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset using two 90 elbows (two 45 elbows equal one 90 elbow) with Rigid Pipe vent systems for Propane and Natural Gas, as per diagram 1.
  • Page 17 INSTALLATION The G36D is approved for a maximum 37 ft. (11.3m) straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas, as per the diagram 3. The shaded area in the diagram 3 shows all allowable combinations of straight vertical and offset to vertical terminations with Rigid Pipe vent systems for Propane and Natural Gas.
  • Page 18: Vertical Termination

    Pipe Length Co-Linear Flex Adapter with Kit# Rigid Pipe Adaptor 946-563 # 510-994 90 Degree Elbow Inner Pipe Adapter with Kit# 946-563 UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 19: Venting Arrangements - Vertical Terminations

    INSTALLATION VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 20: Unit Installation With Horizontal Termination Termination

    Note: Apply sealant "Mill-Pac" to inner termination cap. upside down. pipe and high temperature silicone sealant to outer pipe on every twist- Diagram 3 lock joint. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 21: Unit Installation With Vertical Termination

    18/12 to 20/12 2.29 2.29 2.29 2.29 over 20/12 to 21/12 over 20/12 to 21/12 over 20/12 to 21/12 over 20/12 to 21/12 2.44 2.44 2.44 2.44 Diagram 3 Diagram 7 UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 22: Installation Procedures

    We recommend framing a 10"(254mm) x 10"(254mm) (inside dimensions) hole to give structural rigidity for mounting the termination. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 23: High Elevation

    1/2 psig. (3.45 can be removed for servicing.) Since some kPa). Disconnect piping from valve at pressures municipalities have additional local codes it is over 1/2 psig. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 24: Conversion Kit #773-969 From Ng To Lpg

    INSTALLATION CONVERSION KIT #773-969 FROM NG TO LPG FOR G36D-1 USING SIT 820 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
  • Page 25 27) Connect one end of the supplied green Sparker. ground wire to the lug with the nut and washer from the kit. Sparker Sparker Ground wire from Ignitor Wire Fig. 6 UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 26 36) Check inlet and outlet pressures. 37) Check operation of fl ame control. 38) Check for proper fl ame appearance and glow on logs. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 27: Log Set Installation

    4) Place Log 02-51 on the front right side of the burner. Push the back of the log against the 2 brackets with the notch on the bottom right side of the log fi tting into the right side of the grate. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 28 Log 02-53. 02-75 02-50 02-55 02-53 02-51 02-53 Front Brackets 02-55 Rear Bracket Cutouts 02-50 Notch 02-53 UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 29 Place embers in these 3 locations on the burner tray. 02-51 02-54 Do not block the burner holes in this area adjacent to the Log 02-54 02-75 02-55 02-51 02-50 02-54 UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 30: Standard Flush Door

    Diagram 2. Diagram 2 UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 31: Option 1: Remote Control

    4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 32: Wiring Diagram

    CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 33: Installing The Optional Fan

    Optional: If you require extra space to slide the fan to the back, the left spring can be unhooked from the bracket. 4) Plug the fan to the receptacle as shown in the wiring diagram below. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 34: Operating Instructions

    1) Turn burner OFF using "ON/OFF" switch. condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 35: Normal Operating Sounds Of Gas Appliances

    3) Turn off all electric power to the appliance if service is to be performed. ® ® ® You may shut off the pilot during prolonged non use periods to conserve fuel. Paint - Metallic Black #6309. DO NOT REMOVE THIS INSTRUCTION PLATE 918-473 UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 36: Maintenance

    If the glass gasket requires replacement use a tadpole glass gasket for the Flush Front (Part # 936-155). UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 37: Removing Valve

    9) Disconnect the inlet gas line. that there is a union by the valve, otherwise removal will be almost 10) Disconnect the 2 TP wires and the 2 TH impossible. wires from the valve. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 38: G36D Main Assembly

    Standoff - Top 918-515 Manual 24) 780-013 Standoff - Side/Back 290-969 Conversion Kit - NG to LP *Not available as a replacement part. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 39: G36D Burner Assembly & Log Set

    Defl ector - Right 79) 786-525 Burner Assy - NG/LP 83) * Rear Log Support Bracket 85) 780-930 Log Set 86) * Pilot Defl ector *Not available as a replacement part. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 40: G36D Flush Front Assembly

    135) 940-334/P Glass - Tempered 137) 904-691 U-Clip 139) 936-155 Glass Gasket (Tadpole) 140) 948-042 Spring Hinge - Black *Not available as a replacement part. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 41 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 42 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace G36D Zero Clearance Direct Vent Gas Fireplace ® ® ®...
  • Page 43: Warranty

    UltraGlow inspects each unit thoroughly before it leaves our door. UltraGlow is pleased to extend this one year warranty to the original purchaser is pleased to extend this one year warranty to the original purchaser ®...
  • Page 44 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Printed in Canada © Copyright 2005, FPI Fireplace Products International Ltd. All rights reserved. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace...

This manual is also suitable for:

G36d-ng1G36d-lp1

Table of Contents