opti-solar SC Series Installation And Operation Manual page 7

Lighting control
Table of Contents

Advertisement

Push Buttons
Light Test
PUSH
Manual
Equalize/LVR
HOLD
Manual
Equalize/LVR
Optional Remote LCD Meter for SC-30LC
One Remote LCD Meter can be added to the SC-30LC at any time during or after
installation. The display is a 2x16 LCD meter with backlighting. One pushbuttons is
used to scroll through the displays function.
There are a series of display screens that provide information such as:
• Operating information and data
• Reset Amp-Hours
Press the Light Test Push Button to enter the testing mode to check if the
Lighting Control Switch has been correctly set in order to control the lights
based on desired timer.
Procedure:
1. Select Dip Switch 7 to be ON
2. Press LIGHT TEST push button until the LOAD LED blinking in green
and red in turns.
3. Count 24 hours a day as 24 seconds so 1 hour equals to 1 second and 12
seconds for day time and 12 seconds for night time.
4. If the Lighting Control Switch is placed at 2, the light load will light for 2
seconds for testing.
5. If the Lighting Control Switch is placed at 3/1, the light load will light for 3
seconds and then stop for 8 seconds and light again for 1 second.
6. Press LIGHT TEST push button to return to charge battery/load control
state.
When there is a fault occurring, push Manual Equalize/LVR to reset it.
Battery charge control mode: Hold Manual Equalize/LVR to start equalization
and press it again to stop equalization.
7