62

PROGRAMMING MODE - TEST MODE

PROGRAMMING MODE -
Diagnostic tests:
This program has been added for testing the washer and detecting errors.
Entering the test mode
Data Name
Entering
1. Entering
the test
programming mode
mode
2. Hot
3. Start
1.
According to pressing Start button, test move to the next step.
Number of times
the Start button
is pressed
None
1time
Turns on all lamps and locks the door Displays 1U:XX, 1g:XX and 14:XX alternately (Version)
2 times
Tumble Clockwise.
3 times
Low Speed Spin
4 times
High Speed Spin
5 times
Inlet valve for main water turns on.
6 times
Inlet valve for hot wash turns on.
7 times
Inlet valve for atomizing turns on.
8 times
Inlet valve for bleach turns on.
9 times
Tumble counter clockwise.
10 times
Turn on Circulation Pump.
11 times
Drain Pump turns on.
12 times
Turns on all lamps.
13 times
Button Checks.
14 times
High Speed Spin
15 times
16 times
NOTE
• Make sure the drum is empty when a diagnostic test is performed. Do not use
(display)
Button
Display
Check Point
PDA Signal Check
TEST MODE
Insert service card(Card type), turn on/off toggle
switch(Coin type)
Press the Hot button. Then
display.
Enter the diagnostic test mode.
rpm (40~50)
rpm (600)
rpm (1150)
Water level frequency (255~)
Water level frequency (255~)
Water level frequency (255~)
Water level frequency (255~)
rpm (40~50)
Water level frequency (255~)
Water level frequency (255~)
Displays 1U:XX, 1g:XX and 14:XX alternately (version)
rpm (1150)
this function is not applied in this machine
Description
appears in the
Display
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fh069fd4pFh069fd6pFh069fd7pFh069fdpFh069fd2p

Table of Contents