Command 'N' (15 message) Traffic capture using a Ballard USB 1553 monitor. Use the 'T' command to
see the same messages on the console.
When a BC message is transmitted to an unassigned RT address, "RT no response" (NORES) error is
indicated.
MSG #0170.
ERROR: NORES (not in red)
Commands 'S' and 'I'
These demo commands initialize the SMT or IMT monitor features in the HI-6130 and return to the main
menu, they do not display any information on the console. The SMT is also initialized and used in the 'T'
RT Traffic command.
28
AN-6130PCIe
TIME = 00086918us
CMD1 182A --> 03-R-01-10
CMD2 0C2A --> 01-T-01-10
BUS A
TYPE2: RT to RT