NLTroubleshooting
Malfunction
"E:36 / -10"
"E:60/-2B"
"E:30 / -10" and/or
flashes.
42
Cause and Troubleshooting
Detergent dosage is too high.
▶ Immediate measure: mix a tablespoon of fabric softener
with 0.5 l of water and pour this mixture into the left
compartment (not for outdoor, sportswear and down
textiles).
Reduce the amount of detergent for the next wash
with the same load.
The imbalance detection system has stopped the spin
cycle due to uneven distribution of the laundry.
Redistribute the laundry in the drum.
Remark:If possible, place large and small items of
laundry together in the drum. Laundry of different
sizes is distributed better during the spin cycle.
Water pressure is low.
No solution possible.
The strainers in the water supply are clogged.
▶ Clean the strainers in the water supply.
Water tap is closed.
Open the water tap.
Water supply hose is kinked or pinched.
Make sure that the water supply hose is not
kinked or trapped.
Water level measuring system defective.
Remark:With the error message, the device starts a
pump-down procedure.
First wait approx. 5 minutes until the pumping procedure
1.
has finished.
To reset the error message, turn off the device.
2.
Turn the device back on.
3.
If the error message appears again, please contact
4.
the service.
"After-sales service", Page 51
Voltage monitoring system detects an impermissible
undervoltage.
No solution possible.
Remark:When the supply voltage has stabilized, the
program continues normally.