2. INSTALLATION OF THE DEVICE

Warning! The device must be installed/put into service by a competent person! Before commis-
sioning make sure that neither the thermostat nor the appliance you want to connect to is con-
nected to the 230 V mains. Modifying the device can cause electric shock or product failure.
Caution! The voltage 230 V is displayed when the output of the appliance is switched on. Make
sure that the wires are properly connected and that that there is no risk of electric shock or short
circuit!
Connect your device as follows:
● The pump controller is provided with the supplied flexible tension strap for proper contact
heat transfer. Tightly mount to the mantle of the uninsulated water or heating pipeline (max. 2").
● Connect the 3 wires to the pump you want to control. The marking of the wires are based on
the EU standard: brown - phase, blue - zero, green-yellow - earth.
● Connect the pump controller to the 230 V mains using the pre-mounted connector