CHARACTERISTICS

CONDITIONS FOR APPLICATION
The DCC-9 is an Energy Management System specially designed to allow
the connection of an EV Charger to be connected to a power source
without affecting load calculation.
INSTALLATIONS TYPES
- Group installation
- Wall installation
- Ceiling installation
The DCC-9-BOX6 and DCC-9-BOX3 can also be installed vertically
on the floor.
MAIN POWER SUPPLY (CB)
The DCC-9-BOX can be powered by a 240/208V AC single phase source,
max 125A. The following options are offered by each DCC model:
Models
60A
DCC-9-BOX
DCC-9-BOX-3R
DCC-9-BOX3
DCC-9-BOX6
Voltage and wiring
Terminals size
Certifications
*Approximative and can change without notice.
Main power supply
70A
80A
90A
100A 125A
150A
240/208V AC single phase: L1, L2, Neutral, Ground.
up to 2/0
(CU/AL)
Dimensions
Total weight
*
(H" x W" x D")
200A
12" x 12" x 7.5" 11 lb (4,99 kg)
14" x 13" x 8"
12 lb (5,44 kg)
SEE
DCC-11
39" x 14" x 9"
40.5 lb (18,37 kg)
78" x 14" x 9"
81 lb (36,74 kg)
*