Sleep Mode
When cooling, sleep mode increases the temperature by 1°C per
hour for the first two hours, then maintains the temperature 2°C
above the set temperature for the next six hours. The fan runs at
the lowest speed.
When heating, sleep mode decreases the temperature by 1°C per
hour for the first two hours, then maintains the temperature 2°C
below the set temperature for the next six hours. The fan runs at
the lowest speed.
Press the SLEEP button on the remote control to select sleep
mode. The crescent moon icon will illuminate to indicate that the
appliance is in SLEEP mode.
At time of going to press, the average cost of electricity is £0.11
per unit (kilowatt-hour). The amount you are being charged will be
shown on your electricity bill.
At this cost, the appliance will cost 10p per hour to run either
cooling or heating, of 12p per hour when the resistance heater
operates.
To minimise the power used (and reduce operating costs):
Make sure that the filter is kept clean.
Make sure that the air intakes and exhausts are not obstructed.
Keep doors and windows closed to prevent conditioned air from
escaping, and to prevent exhaust air from re-entering the room.
Use blinds to prevent direct sunlight reaching the room.
Set the temperature higher whilst cooling, or lower whilst heating.
Before cleaning, turn the appliance off using the button on the
control panel (NEVER switch off the power at the mains socket
whilst the appliance is running). Wait until the appliance stops and
then disconnect from the mains supply. The case may then be
cleaned using a damp cloth with a drop of washing-up liquid to
remove any dust or dirt from the case. Do no use stronger
detergents or solvents as these may damage the plastic.
Using a dry 25mm paint-brush, remove any dust from the grilles.
OPERATING COSTS