Installation - Prem-I-Air EH1329 Quick Start Manual

Indoor climate control
Table of Contents

Advertisement

INSTALLATION

The appliance weighs 32kg. In order to comply with Health and
Safety Manual Handling guidelines, two people will be required to
lift it.
Transport and store in an upright position. Leave the unit in an
upright position for at least 3 hours before first use.
Choose the optimum location for the
appliance:
It must be on an external wall with 2m
free clearance on both inside and
outside to allow good airflow
The wall must be able to withstand
the weight of the unit.
The wall must be perfectly flat.
There must be no electrical wiring,
gas pipes, or structural steelwork in
the wall in the area where the
appliance is to be mounted.
Attach the template to the wall using masking tape. Use a spirit
level to ensure that it is perfectly level.
Drill the fixing holes and insert wall plugs.
Using a 135mm core drill, drill the two air intake holes. These
should be drilled with a downwards
slope of between 3° and 5° to make
sure that any water will drain out.
Using a 30mm masonry bit, or a core
drill, drill the hole for the water drain.
This MUST have a downward slope
of between 3° and 5° to make sure
that the water will drain out.
Cut the air intake tubes so that they are 10mm less then the
thickness of the wall. Attach the flanges for the air intake and
exhaust tubes to the tubes using the 10 mm screws provided.
Then fix the tube/flange assembly into the hole. If the outside wall
is accessible, fill the area between the tubes and the wall using
expanding foam, and attach the rubber rings to the outside of the
Page 3