Toshiba TLP-X4100U Service Manual page 14

3lcd data projector
Hide thumbs Also See for TLP-X4100U:
Table of Contents

Advertisement

Optical Pats Disassemblies
Relay Lens disassembly
1
Remove 2 hex screws
2
B
Remove 2 screws
to take the Lens off from the holder.
Note:
There is no mounting direction of the lens.
A
Polarized Glass-Out and Wide view Glass removal
1
Remove 4 hex screws
2
B
Remove 3 screws
and take the Glass Holder, and then pull the polarized
Glass-Out and the wide view glass upwards off. These glasses are mount-
ed for R, G and B LCD panels respectively.
Note:
To avoid the CG and focus alignments slipping off, please be careful to han-
dle the LCD/Prism ass'y.
Note:
Do not replace the LCD panel
separately otherwise it can
not obtain proper picture.
A
and pull the Relay Lens ass'y upward.
A
Fig.3-
A
and take the LCD/Prism ass'y off upward.
A
LCD Panel/Prism Ass'y
A
A
Fig.4-
B
B
1
B
* Glasses should be placed as the
sheet attached side comes to the
LCD panel side.
1
-14-
Holder
Relay Lens
B
Wide view Glass
B
Phase Sheet
Phase Sheet
Polarized Glass-
Out
Fig.3-
2
Fig.4-
2