Beko MWDR24100SS24 Service Manual page 28

Microwave drawer
Hide thumbs Also See for MWDR24100SS24:
Table of Contents

Advertisement

STOP SWITCH, SECONDARY INTERLOCK, THIRD DOOR SWITCH AND MONITOR SWITCH REMOVAL
1. Follow the Microwave Drawer disassembly as previously
stated
2.
Open the drawer and keep it open.
3. To discharge the high voltage capacitor, wait for 60
seconds.
4. Disconnect the wire leads of each switch.
5. Remove the screw holding the latch hook to the oven
flange.
6. Remove the latch hook from the oven flange.
7. Remove each switch from the latch hook by pushing the
one (1) stopper tab holding each switch.
8. Now, each switch is free.
Latch Hook Left
STOP SWITCH, SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH ADJUSTMENT
1. Follow the Microwave Drawer disassembly as previously
stated
2.
Open the drawer and keep it open.
3. To discharge the high voltage capacitor, wait for 60
seconds.
4. If the door sensing/third door switch, secondary interlock
switch and monitor switch do not operate properly due
to a misadjustment, the following adjustment should be
made.
6. Loosen the screw holding latch hook to the oven cavity
flange.
7. With drawer closed, adjust latch hook by moving it back
and forth, and up and down. In and out play of the door
allowed by the upper and lower position of the latch hook
should be less than 0.5mm. The vertical position of the
latch hook should be adjusted so that the secondary
interlock switch is activated with the drawer closed. The
horizontal position of the latch hook should be adjusted
so that the monitor switch and drawer sensing switch
are activated with the drawer closed.
8. Secure the screws with washers firmly.
9. Check all of the switches operation.
Re-install
1. Re-install each switch in its place. The secondary interlock
switch is in the lower position and the monitor switch is
in the top position, located on the right side of the unit.
The door sensing switch is in the bottom position and
the third door switch is in the top position on the left side
of the unit.
2. Re-connect wire leads to each switch. Refer to pictorial
diagram.
3. Secure the latch hooks with mounting screws to oven
flange.
4. Make sure that the monitor switch is operating properly
and check continuity of the monitor circuit.
chapter "Test Procedure" and "Adjustment procedure".
Latch Hook Right
After adjustment, check the following.
1. In and out play of door remains less than 0.5mm when
in the latched position. First check upper position of latch
hook, pushing and pulling upper portion of drawer toward
the oven face. Then check lower portion of the latch hook,
pushing and pulling lower portion of the door toward the
oven face. Both results (play in the door) should be less
than 0.5mm.
2. The secondary interlock switch interrupts the circuit
before the door can be opened.
3. Monitor switch contacts close when door is opened.
4. Door sensing switch contacts open when door is
opened.
5.
Reassemble the unit
around door with an approved microwave survey meter.
(Refer to Microwave Measurement Procedure.
28
and check for microwave leakage
Refer to

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mwdr24100ss

Table of Contents