Download Print this page

Duracell D350-Ml Installation Manual page 18

Grid support utility interactive inverter

Advertisement

DURACELL:
POWER CENTER
7.4 Status LED Indicator
The LED flashes five times at start up. All green flashes (ls gap) indicate
normal start up.
7.4.1 Start-up Modes
Flashing green five times (0.3s gap): Start-up success
Flashing Red five times {0.3s gap): Start-up failure
7.4.2 Run Modes
Flashing Fast Green (ls gap): Producing power.
Flashing Slow Green (2s gap): Producing power but one input is
abnormal.
Flashing Slow Green (4s gap): Producing power but there is no
communication with the DTU.
Flashing Red (ls gap): AC grid invalid (Voltage or frequency out
of range).
Flashing Red (0.5s gap): There is a non-grid related fault.
7 .4.3 Other Status
Flashing Red and Green alternately: Firmware is corrupted .
Note: All faults are reported to the DTU. Refer to the local App of the DTU or Power Center+ Monitoring Platform for
more information.
7.5 On-site Inspection (For qualified installers only)
To troubleshoot an inoperable microinverter, follow the steps in the order shown.
1.
Verify the utility voltage/frequency are within ranges as shown in the technical data.
2.
Check the connection to the utility grid. Verify utility power is present at the inverter in question by removing AC, then
DC power. Never disconnect the DC wires while the microinverter is producing power. Re-connect the DC module
connectors and watch for five short LED flashes.
3.
Check the AC branch circuit interconnection between all the microinverters. Verify each inverter is energized by the
utility grid as described in the previous step.
4.
Make sure that any AC breakers are functioning properly and are closed.
5.
Check the DC connections between the microinverter and the PV module.
6.
Verify the PV module DC voltage is within the allowable range as shown in the technical data.
7.
If the problem persists, please call Power Center customer support.
II\
Warning! Do not try to repair the microinverter. If the troubleshooting fails, please return it to the factory for
L_l_i
replacement.
Models: D350-Ml / D700-M2 / D1500-M4
Installation Manual
Status
Statvs LED
LED
15

Advertisement

loading

This manual is also suitable for:

D700-m2D1500-m4