BEKO THAI NF70CM REFRIGERATORS(USA)
09.09.2019 / REV NO: 01
11.11. Sensor Error
In case of a sensor error, when the Power is "ON", no component shall be driven for 15 minutes.
FRZ Air Sensor Error/FRZ Fan
Activated and stopped with the compressor.
It is operated at DC Fan x 1400 rpm.
FRZ Air Sensor Error/Compressor
When another compartment cannot make a decision for Cut-in/Cut-out (Caution)
30 minutes on, 40 minutes off
FRZ Eva Sensor Error/Frz Fan
Activated and stopped with the compressor.
It is operated at DC Fan x 1400 rpm.
FRZ Eva Sensor Error/Compressor
***NORMAL COOLING***
When another compartment cannot make a decision for Cut-in/Cut-out (Caution), 30
minutes on, 40 minutes off
If FF Air Sensor or FRZ Air Sensor is not faulty, it is operated in accordance with these
sensors.
FRZ Air Sensor Error/Defrost/Frz Fan
Fan is stopped unconditionally.(Frz defrost is not initiated when there is Frz Air sensor
error.)
FRZ Eva Sensor Error/Defrost/Frz Fan
Fan is stopped unconditionally.
FRZ Eva Sensor Error/Frz Defrost Heater
It is activated during the whole FRZ defrost process.
FRZ Eva Sensor Error/Defrost/Compressor
***NORMAL DEFROST***
Defrost input algorithm is the same.
Defrosting is stopped after 20 minutes.