ENGLISH PROBLEM SOLUTION GUIDE Problem Potential cause Solution Check the connection to wall socket The unit is disconnected Check the power on the socket The unit display does not turn on General switch deactivated Turn on main switch under the unit display Fautly thermoregulator Replace the thermoregulator (G) The Ambient temperature is too high...
ENGLISH C. REFRIGERATING UNIT EXTRACTION (OPERATIONS ON POINTS A - B TO BE ACCOMPLISHED FIRST) C1. Move all the alluminium rods C2. Unscrew all the bolts and C3. After removing all the towards left or unscrew them remove central alluminium plastic clips extract all the (depends on the model) pannel right side...
Page 5
ENGLISH WHITE LEDS E5. Disconnect the broken LED E6. Extract the broken LED strips E7. Insert the new LED strips in the E8. Reconnect to the power supply strips from the power supply from the guide, operating with aluminium profiles and extract matching the polarity a screwdriver the 4 cables from the holes in...
ENGLISH H. PROBE REPLACEMENT (OPERATIONS ON POINT A ARE TO BE ACCOMPLISHED FIRST) H1. After extracting the H2. Unscrew the protection carter H3. Fasten the probe and H4. Reconnect the probe to the thermoregulator disconnect the of the probe ( unit display’s left carter passing along the lead thermoregulator probe from the terminal ...