Download Print this page

Gemo DP102-V Manual page 3

Digital potentiometer

Advertisement

GEMO
SET
Back
Press "Back"
to return to the
SET
top of
parameters
programming
block
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti.
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye
Tel: +90-312-3503900, Fax: +90-312-3511117
PROGRAMMING SET
Press 2 sec.
SET
SEt
LoL .. UPL
SET
Prog. end
PROGRAMMING OTHER PARAMETERS
+
Press for 2 sec.
SET
CodE
Enter 162
Select
d.Pnt
Decimal Point
Scale High
Sc.Hi
Sc.Lo .. 9999
Scale Low
Sc.Lo
-1999 .. Sc.Hi
Upper Limit
UPL
LoL .. Sc.Hi
Lower Limit
LoL
Sc.Lo .. UPL
Power on
Pon.S
State
Ramp Up Time
rP.U.t
1 .. 999 secs
Ramp Down Time
rP.d.t
1 .. 999 secs
Select Up key
UP.k.F
Press Function
Select Down key
dn.k.F
Press Function
Select Up input
UP.i.F
Press Function
Select
Down input
dn.i.F
Press Function
ot.i.d
1 .. 999
SET adjust
SECU
permission
For; UP.k.F / UP.i.F = o.inc, dn.k.F / dn.i.F = o.dec,
End of Prog.
adjusted value is saved as new SET value.
SET is adjusted
(if SECU = SET.Y).
Analog output is updated
while SET is adjusted
(during 2. SET and later)
Enter 162 to pass
to parameter prog. mode
0
0.0
0.00
0.000
Analog Out = 10V or 20mA
when SET = Sc.Hi
Analog Out = 0V or 4mA
when SET = Sc.Lo
Upper limit for SET;
SET <= UPL
Lower limit for SET;
SET >= LoL
o.LoL: Analog Out = LoL
o.SEt: Analog Out = SET
Set.r: Analog Out ramps up
from LoL to Set
Ramp up time in seconds
from LoL to SET
Ramp down time in seconds
from SET to LoL
no.Fn: No function
SET: Analog Out = SET
SET.r: Analog Out ramps up to SET
o.inc: Analog Out increments
"ot.i.d" amount until reaches to UPL
no.Fn: No function
LoL: Analog Out = LoL
LoL.r: Analog Out ramps down to LoL
o.dec: Analog Out decrements
"ot.i.d" amount until reaches to LoL
no.Fn: No function
SET: Analog Out = SET
SET.r: Analog Out ramps up to SET
o.inc: Analog Out increments
"ot.i.d" amount until reaches to UPL
no.Fn: No function
LoL: Analog Out = LoL
LoL.r: Analog Out ramps down to LoL
o.dec: Analog Out decrements
"ot.i.d" amount until reaches to LoL
Increment and/or decrement amount for
a key or a digital input press in case "o.dec"
or "o.inc" function is selected.
SEt.Y: SET value may be adjusted, SET menu is active
SEt.n: SET value may NOT be adjusted, SET menu is NOT active
3
Upper Display
Enter "555"
CodE
for factory
reset
SET
"YES" / "nO"
• To return to factory settings:
Code > 555 > select "yes" >
Press "SET"
Factory SET Values:
Set : 0.00
d.Pnt : 0.00
Sc.Hi : 50.00
Sc.Lo : 0.00
UPL : 50.00
LoL : 0.00
Pon.S : o.LoL
rP.U.t : 30
rP.d.t : 30
UP.k.F : o.inc
dn.k.F : o.dec
UP.i.F : o.inc
dn.i.F : o.dec
ot.i.d : 0.01
SECU : SEt.Y
http://www.gemo.com.tr
e-posta: info@gemo.com.tr

Advertisement

loading

This manual is also suitable for:

Dp102-ma