Jøtul FS 73 Installation Instructions Manual page 9

Advertisement

ENGLISH
Outside air connection (optional)
If an outside air connection has been ordered, it should be
installed at this point. See the instruction manual for the outside
air connection (item no. 51046710)
4.2 Installation
Log store and base
Fig. 5
1. Centrally position the log store (A) approx. 120 mm in front
of the fireproof board (B).
Fig. 6
A
2. Apply acrylic adhesive along the front edge (A).
40
B
A
Fig. 7
3. Apply adhesive along the vertical edges (B) of the base (A).
Push the base against the fireproof board. It is important
to maintain the minimum allowable clearance of 70 mm
between the fireproof board and the wall (see Fig. 1).
Fig. 8
4. Glue the log store and base together.
B
B
A