Digital clock thermostat

Advertisement

5. Connection
Power is supplied via L and N (see technical data); the
connection to the boiler is made via a relay contact.
!
Secure device (8119200 + 8120200) with an upstream
type B or type C circuit breaker (EN 60898-1) with a
maximum of 10 A.
!
The external input is active, therefore do not use exter-
nal voltage. The connected contact must be floating.
At 8120200, the input is not safely separated from the
mains, therefore only connect insulated components.
!
Disconnect the boiler from mains supply before connect-
ing the thermostat.
!
In order to eliminate the possibility of EMC interference,
always lay the mains supply feed separate from the
external input (if one is being used).
!
Faulty connections will damage the device.
RAMSES 811 top3
L External sensors such as a floor sensor (9070321) or a
temperature sensor (9070459) can be connected to the
external input (ext. input).
10 (2) A
Ext. input
N
L
L
RAMSES 812 top3
!
At 8120200, the external input is not safely sepa-
rated from the mains, therefore only connect insulated
components.
10 (2) A
230-240 V / 50 Hz
Ext. input
N
L
L
RAMSES 812 top3 16A
L
N
N
L
L
RAMSES 813 top3 HF
L RAMSES 813 top3 HF and various receivers provide a
radio-controlled system for room temperature control.
The following sets are available:
1. RAMSES 813 top3 HF Set 1
Set 1: 1 x RAMSES 813 top3 HF with receiver REC 1
(1 channel)
L N
7 8
C1
1 2 3
N
L
L
Receiver REC 1
RAMSES 813 top3 HF
C1
Button channel 1
Status display channel 1
Level display for
reception quality
Antenna connection