7.1

Setting the CAN address

The CAN address of the device is set using the two address selector switches HIGH and LOW.
Addresses 1 to 250 (01 hex to FA hex) can be used in a CAN network. The address is set using
the hexadecimal numbering system. The LOW selector switch is for the low-order digit and the
HIGH selector switch is for the high-order digit.
Notice!
i
Each address may only occur once in the system, otherwise network conflicts will occur.
The address 0 (00 hex, set on delivery) ensures that the device is disconnected from the
remote communication. This means that the device does not appear in the system, even if it is
connected to the CAN bus.
HIGH
0
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
F
Table 7.5: CAN addresses
2023-03 | 08 | F01U306898
LOW
0
1 to F
0 to F
0 to F
0 to F
0 to F
0 to F
0 to F
0 to F
0 to F
0 to F
0 to F
0 to F
0 to F
0 to F
0 to F
0 to A
B to F
User manual
Address
Stand-alone
1 to 15
16 to 31
32 to 47
48 to 63
64 to 79
80 to 95
96 to 111
112 to 127
128 to 143
144 to 159
160 to 175
176 to 191
192 to 207
208 to 223
224 to 239
240 to 250
Reserved