CORNING OptiTect Gen III Series Quick Start Manual

Local convergence cabinet

Advertisement

Quick Links

related literature |
003-735
1.

General

This document describes installation of a splitter box kit into the Corning Optical Communications
OptiTect
®
local convergence cabinet, Gen III series (Figure 1) to provide additional capacity.
2.

Carton Contents

Splitter box kit (Figure 2) (p/n FDH-G3-
SplTrBX-KITVZ), consisting of
(1) Splitter box
(1) Splitter box plate
(3) #6-32 x .50 stainless steel panhead
screws
(1) Standard recommended procedure
(Srp) 003-979-AEN
STANDARD RECOMMENDED PROCEDURE 003-979-AEN | ISSUE 1 | AprIl 2014 | PAGE 1 OF 5
®
Instruction, OptiTect
OptiTect
Cabinet, Gen III Series,
Splitter Box Kit
p/n 003-979-AEN, Issue 1
Gen III local Convergence Cabinet
TPA-4652
®
local Convergence
Splitter box (x1)
Underside
Screw (x3)
view
Figure 1
Top view
Plate (x1)
Figure 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OptiTect Gen III Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CORNING OptiTect Gen III Series

  • Page 1 ® 003-735 Instruction, OptiTect Gen III local Convergence Cabinet General This document describes installation of a splitter box kit into the Corning Optical Communications OptiTect ® local convergence cabinet, Gen III series (Figure 1) to provide additional capacity. Figure 1...
  • Page 2 Tools and Materials Required • phillips screwdriver • 216B tool or a -in nutdriver (for entry into the interior of the cabinet) • Dry-process connector cleaning supplies Precautions WARNING: Never look directly into the end of a fiber that may be carrying laser light. laser light can be invisible and can damage your eyes.
  • Page 3 Step 3: Align the holes on the plate with the screw holes on the panel and secure the plate with the three screws provided in the kit. TPA-4654 Figure 4 Step 4: Install four splitters inside the splitter box (Figure 5) and secure them to the box with the captive fasteners.
  • Page 4 Store the connectors in the connector parking field on the cabinet door. To properly Step 6: close the door without pinching fibers: Use fields C and D when installing up to 288 fibers. • Use fields C, D, and E when installing up to 432 fibers •...
  • Page 5 A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2014 Corning Optical Communications. All rights reserved.

Table of Contents