Isobus Spreader; Teejet Section Control Module - TeeJet Technologies Matrix 908 User Manual

Field computer
Table of Contents

Advertisement

ISOBUS Spreader

If an ISOBUS Electronic Control Unit (ECU) is present, BoomPilot automatic section control and automatic application mapping will be
available.
All ISOBUS rate control configurations should be setup before starting a job.
X Spreader, Console Only – Regulation mode on the ISOBUS device should be set to "Manual".
X Spreader with Optional Spreader On/Off Switch – Automatic or manual regulation mode on the ISOBUS device should not affect
the following options.
The Vehicle Chevron
is used to turn BoomPilot Automatic Application Control on or off.
X On – application will automatically turn on/off when exiting/entering previously applied areas or boundaries. Spreader On/Off
Switch must be in the ON position.
– BoomPilot Status icon is green
X Off – application is controlled manually using the Spreader On/Off Switch or Start/Stop key on the ISOBUS Operation screen.
– BoomPilot Status icon is red
NOTE: Application can be manually controlled while in Automatic BoomPilot mode using the Start/Stop key on the ISOBUS Operation
screen or the Optional Spreader On/Off Switch.

TeeJet Section Control Module

Before starting a job, all Section Control Module configurations should be setup by creating and activating a TeeJet CAN device (see
"No.4 Establish an Implement through the Device Wizard" on page 16).
X Section Control Module with a Switchbox or ISM – SmartCable, Section Driver Module (SDM) or Switch Function Module (SFM)
and a switchbox or Implement Status Module (ISM) is present. Automatic/manual boom switch must be in the "Auto" position.
X Section Control Module only – SmartCable, Section Driver Module (SDM) or Switch Function Module (SFM) is present.
The Vehicle Chevron
is used to turn BoomPilot Automatic Application Control on or off.
X On – application will automatically turn on/off when exiting/entering previously applied areas or boundaries. Master Switch and
section switches must be in the ON position.
– BoomPilot Status icon is green
X Off – application is controlled manually using the Master Switch or section switches.
– BoomPilot Status icon is red
NOTE: Application can be manually controlled while in Automatic BoomPilot mode using the master switch or individual section
switches.
Matrix 908 Field Computer
41
98-01578-ENUS R2

Advertisement

Table of Contents
loading