Oregon Scientific PSL01A User Manual
Oregon Scientific PSL01A User Manual

Oregon Scientific PSL01A User Manual

Full weather station with radio controlled clock

Advertisement

Full Weather Station with Radio Controlled Clock
(Model #: PS-L01 / PS-L01U)
User Manual
PS-L01_GB-final
1
8/8/03, 11:35 AM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSL01A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Oregon Scientific PSL01A

  • Page 1 Full Weather Station with Radio Controlled Clock (Model #: PS-L01 / PS-L01U) User Manual PS-L01_GB-final 8/8/03, 11:35 AM...
  • Page 2 PS-L01_GB-final 8/8/03, 11:35 AM...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS About this guide ... 2 Product overview ... 3 Getting started ... 8 Batteries ... 8 AC power adapter ... 8 Switch between modes ... 8 Change settings ... 9 Remote unit setup ... 9 Clock ... 10 Alarm ...
  • Page 4: About This Guide

    ABOUT THIS GUIDE Congratulations on your selection of the Philippe Starck with Oregon Scientific Full Weather Station with Radio Controlled Clock (PS-L01 / PS-L01U). This powerful device bundles time keeping, alarm, indoor and wireless outdoor temperature and humidity monitoring, and weather forecasting into a single tool you can use from the convenience of your home.
  • Page 5: Product Overview

    PRODUCT OVERVIEW TOP VIEW PS-L01_GB-final DESCRIPTIONS Snooze / Light button (→ 11, 17) Light sensor (→ 17) 8/8/03, 11:35 AM...
  • Page 6: Lcd Display

    LCD DISPLAY PS-L01_GB-final DESCRIPTIONS Low battery icon (→ 8) Clock (→ 10) Barometer (→ 13) Weather forecast (→ 14) Moon phase (→ 12) Calendar (→ 12) Temperature and humidity (→ 14) Alarm (→ 11) 8/8/03, 11:35 AM...
  • Page 7: Back View

    BACK VIEW PS-L01_GB-final BUTTON DESCRIPTIONS Select – switch modes / change settings Up – increase setting / activate auto-synch (→ 10) Down – decrease setting / deactivate auto-synch (→ 10) Alarm – activate / deactivate alarm (→ 11) Channel – switch remote unit (→ 15) 8/8/03, 11:35 AM...
  • Page 8: Bottom View

    BOTTOM VIEW PS-L01_GB-final DESCRIPTIONS Battery compartment (→ 8) Light sensitivity knob (→ 18) Reset button (→ 8, 18) Backlight switch (→ 17) DC power input jack (→ 8) NOTE AC power adapter not shown. 8/8/03, 11:35 AM...
  • Page 9: Remote Unit

    REMOTE UNIT PS-L01_GB-final DESCRIPTIONS Temperature / Trend display Low battery icon Humidity / Trend / Comfort Level display °C / °F switches Channel switches Reset button Battery compartment Wall-mount hole Battery compartment lid 8/8/03, 11:35 AM...
  • Page 10: Getting Started

    GETTING STARTED BATTERIES Batteries for the remote and main units are supplied with this product. Replace them whenever the low battery signal ( ) displays. Remove the battery compartment lid on the bottom of the main unit, and insert the batteries. Use a small Phillips screwdriver to remove the remote unit compartment lid.
  • Page 11: Change Settings

    CHANGE SETTINGS Press and hold SELECT for 2 seconds. Then, press UP or DOWN to change each setting. Press SELECT to switch options. REMOTE UNIT SET UP Up to 3 remote units can be used with this product to monitor outdoor temperature and humidity. The measurement unit (°C or °F) and channel number (1, 2, or 3) switches are located in the battery compartment, and should be set prior to installation.
  • Page 12: Clock

    CLOCK This product can automatically synchronize the date and time with official time-keeping organizations in Frankfurt, Germany (PS-L01) or Rugby, England (PS-L01U). When the unit is within 1500 km (932 miles) of a RF signal, the reception icon will blink during reception. RECEPTION Reception takes 2 –...
  • Page 13: Set Alarm

    SET OR CHANGE THE CLOCK Press SELECT to switch to the Clock Mode. The time will flash. Press and hold SELECT for 2 seconds to enter the setting mode. Select the 12/24-hour format, hour, and minute. Press UP or DOWN to change the setting. Press SELECT to confirm.
  • Page 14: Calendar

    To turn the alarm off completely (deactivate it for the next day), press ALARM. CALENDAR SET DATE Clock auto-synchronization must be deactivated before you manually set the date. (→ 10) Press SELECT several times until the calendar area flashes. Press and hold SELECT for 2 seconds to enter the calendar setting mode.
  • Page 15: Barometer

    BAROMETER This product tracks barometric pressure changes over the past 24 hours to provide the weather forecast (→ 14) and a trend line showing the direction of barometric change. Barometric changes are measured by the main (indoor) unit. BAROMETRIC TREND The barometric trend arrow for the last 30 minutes is always displayed.
  • Page 16: Set Unit And Altitude

    SET UNIT AND ALTITUDE You can set the unit of measurement (mb/hPa or inHg) and altitude. Setting the altitude allows the product to take more accurate barometric measurements. Press SELECT 2 times until the Barometer Area flashes. Press and hold SELECT for 2 seconds. Select altitude (-100 meters to 2500 meters in increments of 10) and the unit of measurement (mb/hPa or inHg).
  • Page 17 Outdoor measurements are collected by the remote unit. Temperature is give at the top; humidity is below. VIEW MIN / MAX / CURRENT MEASUREMENTS Press SELECT 3 times until the Temperature and Humidity Areas flash. Press UP or DOWN to scan the readings.
  • Page 18: Comfort Zone

    Searching No sensor Sensor found NOTE Signals from household electrical appliances such as doorbells and home security systems can cause temporary reception failures between the indoor and outdoor units. This is normal and does not affect the general performance of the product. Reception will automatically resume once the interference ends.
  • Page 19: Backlight

    TRENDS The trend arrow for the last 30 minutes always displays. Indoor and outdoor temperature and humidity trends are shown separately. Trend Temperature Relative Humidity +0.5 °C Steady Steady -0.5 °C PS-L01_GB-final SET UNIT While in Temperature / Humidity Mode, press SELECT for 2 seconds.
  • Page 20: Reset System

    Move it to the “AUTO” position to enable continuous backlight controlled by light intensity. When activated, the backlight will be on whenever the unit perceives that the room is dark. The Light Sensitivity knob is located in the battery compartment. Rotate to adjust. When activated, the continuous backlight will be half as bright as usual.
  • Page 21: Warnings

    WARNINGS This product is designed to give you years of service if handled properly. Observe the following guidelines: • Never immerse the unit in water. This can cause electrical shock and damage the unit. • Do not subject the main unit to extreme force, shock, or fluctuations in temperature or humidity.
  • Page 22 Problem Symptom Remedy Strange date / Calendar Change language month (→ 12) Backlight Plug in AC power continuous adapter Check the backlight BACKLIGHT switch (→ 8, 17) Cannot Check batteries Remote locate (→ 8, 9) unit remote unit Check location (→...
  • Page 23: Specifications

    Problem Symptom Remedy If it still fails, you may be too far from a signal. Disable auto- Cannot synchronization change (→ 10) clock Strange Set altitude / unit Baro reading (→ 14) PS-L01_GB-final SPECIFICATIONS Main unit dimensions L x W x H 181 x 45 x 185.3 mm (7.1 x 1.77 x 7.3 inches) Weight...
  • Page 24 Remote Unit: -20 ˚C to 60 ˚C (-4 ˚F to 140 ˚F) 0.1 °C (0.2° F) Resolution 20 °C to 25 °C (68 °F to 77 °F) Comfort (see also, Relative humidity) Memory Minimum / maximum Trend +/- 0.5 ˚C (+/- 0.9 ˚F) change Relative humidity Range Main &...
  • Page 25: Additional Resources

    Channel No. 1, 2, or 3 °C or °F Unit Radio-controlled clock Synchronization Auto or disabled Clock display HH:MM:SS Hour format 12hr AM/PM (MSF format) 24hr (DCF format) Calendar DD/MMM; weekday selection in 5 languages (E, D, F, I, S) Moon phase High, medium, and low tide Alarm...
  • Page 26: Ec Declaration Of Conformity

    R&TTE Directive 1999/5/EC (appendix II) and carries the respective CE marking. VS-Villingen / Germany August 2003 Gerhard Preis R&TTE Representative of manufacturer RTT&E Compliant Countries: All EC Countries, Switzerland CH , and Norway © 2003 Oregon Scientific. All rights reserved. 8/8/03, 11:35 AM...

This manual is also suitable for:

Ps-l01Ps-l01uStarck ps-l01Starck ps-l01u

Table of Contents