BestCode NExT 8 Series Technical Manual page 7

Hide thumbs Also See for NExT 8 Series:
Table of Contents

Advertisement

WARNING
PERSONAL INJURY & EQUIPMENT DAMAGE: The resistance between equipment Cabinet or Printhead
and the factory earth ground should measure between 0 and 1 ohm. If that value is greater than 1
ohm, a dedicated earth ground may be required. This test should be regularly performed to ensure the
quality and reliability of the electronic circuitry.
WARNING
EQUIPMENT DAMAGE: The Next Series 8 CIJ must be Grounded/Earthed! Failure
to provide adequate grounding/earthing will result in damage to the circuit board,
printhead, and the power supply. This damage will occur over time. The Next
Series 8 CIJ Power Supply generates a DC Ground to support the function of the
Printer, but this does not protect from static or power surges.
Supply Power
WARNING
PERSONAL INJURY & EQUIPMENT DAMAGE: When connected to Supply Power, this Printer produces
Lethal Voltages. Only BestCode trained individuals should service or maintain the Printer. Follow all
local safety codes and regulations. Unless necessary, always disconnect the Printer from Supply Power
when performing maintenance. Unless necessary, never operate the Printer while the Electronics
Compartment door is open. Failure to observe these warnings may result in severe injury or death.
WARNING
PERSONAL INJURY & EQUIPMENT DAMAGE: Make sure that the Supply Power is within the acceptable
ranges for operating the Printer. These ranges are clearly marked next to the Power Entry Module on
the side of the Printer.
100-240Vac
@240V, 50hz – 22.5V Amps (.225 watts)
50-60Hz
@ 120V, 60hz – 45V Amps (.45 watts)
3A MAX