Accessories List Safety Attentions Please read the following safety instructions before installation. And ensure that the unit is The package includes the following items. Please check when open the box: installed correctly. Please observe all instruction in order to avoid any injury or damage to 1.
Product Introductions Specification and Operation Instructions Specification Working Principle and Functions Model ERVQ-B150-1B1(H01) / ERVQ-B150-1B1 (H02) The wall mounted energy recovery ventilator, which integrates air purification and energy recover function. This product is made of supply fan, exhaust fan, heat exchanger, primary Airflow ( m3/h) filter, medium filter, activated carbon filter and HEPA filter at OA side, primary filter at RA Volt (V)
Operation Instructions Operation Instructions 2. Under any mode, the unit will be switched to “Manual” mode when user presses “Speed” Buttons function introduction: button, then press “Speed” again to enter SA/EA fan setting. When “SA” flashes, press 1. Press the button “on/off” to turn on or off the machine; “Speed”...
Page 5
Operation Instructions WIFI Function Installation of “Smart Life” User manual of remote controller Button function introduction: 1. If your phone is Android system, please search and download the APP of “Smart Life” from Google play, while the IOS system can download it from the Apple App Store. 1.
Jacket into the holes age menu. Attention: The OA inlet and EA outlet holes size is according to the Holtop acces- B. Click the symbol , entering into the setting interface, click “name” button to modify sories (PVC pipes).
Page 7
Installation Instructions Installation Instructions Installation Instructions 5. Put the assembled ducts into the wall, ensure the Side installation rain cover towards down, seal the gaps between the duct and the wall. 1. Paste the 3mm side sealing rings on the flanges, connect the flanges to the ventilator side by 8pcs M3x12 bolts and 8pcs M3 nuts.
Installation and Maintenance Maintenance 6. Hang the ventilator on the installation panel, user can adjust the 4 pieces M5x18 hanging Maintenance of heat exchanger screws on the back of the ventilator to suit the installation panel. 7. According to the wall thickness, cut the suitable length of the flexible pipes, connect the The plate heat exchanger is installed at the central right of the ventilator, it is the air to air pipes to the OA inlet grille and EA outlet grille, also the rain cover, etc.
Failure Diagnose Failure diagnose User can make self trouble shooting following below chart in case of any failure. Phenomenon Possible reasons Solutions 1.Check if the plug is loosen and reconnect it 1.Loosen or bad contact of power plug The display 2.Replace the power cable of 2.Broken of power cable doesn’t start up...
Need help?
Do you have a question about the ERVQ-B150-1B1 H01 and is the answer not in the manual?
Questions and answers