Your KIDDE smoke alarm is designed to detect products of combustion using the ionisation
technique. It contains 0.9 microcurie of Americium 241, a radioactive material.
WARNING: BATTERY DOOR WILL NOT CLOSE UNLESS BATTERY IS PRESENT.
REMOVAL OF BATTERY WILL RENDER THE SMOKE ALARM INOPERATIVE.
IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND KEEP THIS MANUAL
NEAR THE ALARM FOR FUTURE REFERENCE
CONTENTS OF THIS MANUAL
1
-
RECOMMENDED LOCATIONS FOR SMOKE ALARMS
2
-
LOCATIONS TO AVOID
3
-
INSTALLATION INSTRUCTIONS
4
-
OPERATION AND TESTING
5
-
NUISANCE ALARMS
6
-
MAINTENANCE
7
-
LIMITATIONS OF SMOKE ALARMS
8
-
GOOD SAFETY HABITS
9
-
SERVICE AND WARRANTY
This smoke alarm uses an extremely small amount of radioactive element in the ionisation
chamber (see Section 9). Do not try to repair the smoke alarm yourself.
Refer to the instructions in Section 9 for service.
1. RECOMMENDED LOCATIONS FOR ALARMS
Locate the first alarm in the immediate area of the bedrooms. Try to protect the exit
path as the bedrooms are usually farthest from the exit. If more than one sleeping
area exists, locate additional alarms in each sleeping area.
Locate additional alarms to protect any stairway as stairways act like chimneys for
smoke and heat.
Locate at least one alarm on every floor level.
Locate an alarm in every bedroom where a smoker sleeps.
Locate an alarm in every room where electrical appliances are operated (i.e. portable
heaters or humidifiers).
Locate an alarm in every room where someone sleeps with the door closed. The
closed door may prevent the alarm from waking the sleeper.
Smoke, heat and combustion products rise to the ceiling and spread horizontally.
Mounting the smoke alarm on the ceiling in the centre of the room places it closest
to all points in the room. Ceiling mounting is preferred in ordinary residential
construction.
For mobile home installation, select locations carefully to avoid thermal barriers that
may form at the ceiling. For more details, see MOBILE HOME INSTALLATION on
page 2.
Only models 0916, 0916LL and 0918 are suitable for installing in caravans or mobile
homes.
When mounting an alarm on the ceiling, locate it at a minimum of 4" (10cm) from the
side wall and 2 feet (60.96cm) from any inside corner (see Diagram A).
When mounting the alarm on the wall, use an inside wall with the top edge of the
alarm at a minimum of 4" (10cm) and a maximum of 12" (30.5cm) below the ceiling,
and at least 2 feet (61cm) from any inside corner (see Diagram A).
Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or
room is more than 30 feet (9.1m) long.
11:22 am
Page 1
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 0915 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kidde 0915

  • Page 1 11:22 am Page 1 ENGLISH Your KIDDE smoke alarm is designed to detect products of combustion using the ionisation technique. It contains 0.9 microcurie of Americium 241, a radioactive material. WARNING: BATTERY DOOR WILL NOT CLOSE UNLESS BATTERY IS PRESENT.
  • Page 2: Locations To Avoid

    0915 etc Guide 23/8/01 11:22 am Page 2 BEDROOM BEDROOM BEDROOM When wall mounting, the KITCHEN When mounting in a “A” line should be hallway, the “A” line horizontal and the “UP should be parallel with FOR WALL MOUNTING” the hallway.
  • Page 3: Operation And Testing

    CAUTION! EARLY WARNING FIRE DETECTION IS BEST ACHIEVED BY THE INSTALLATION OF The Model 0915 Smoke Alarm is powered by a 9V carbon zinc battery (alkaline battery may THE FIRE DETECTION EQUIPMENT IN ALL ROOMS AND AREAS OF THE HOUSEHOLD AS also be used).
  • Page 4: Service And Warranty

    If after reviewing this manual you feel that your smoke alarm is defective in any way, do not tamper with the unit. Return it for servicing to: KIDDE Safety, Thame Park Road, Thame, • A battery powered detector must have a battery of the specified type, in good condition and Oxfordshire, OX9 3RT.
  • Page 5 NEDERLANDS SLAAPKAMER KEUKEN MINIMUM PLAFOND DOOD LUCHT Uw KIDDE rookalarm is ontworpen voor de detectie van verbrandingsproducten met behulp RUIMTE 10cm van ionisatie. Het bevat 0,9 microcurie Americium 241, een radioactieve stof. MINIMUM WOONKAMER HIER NOOIT WAARSCHUWING: DE BATTERIJKLEP GAAT ALLEEN DICHT WANNEER ER EEN BATTERIJ SLAAPKAMER IN ZIT.
  • Page 6: Instructies Voor De Installatie

    0915 etc Guide 23/8/01 11:22 am Page 10 LET OP! VROEGE DETECTIE VAN BRAND WERKT HET MEEST EFFICIËNT WANNEER ER IN ALLE Bij installatie op een Bij installatie in een KAMERS EN RUIMTEN VAN HET HUIS BRANDALARMS AANWEZIG ZIJN, VOLGENS DEZE muur, moet de “A”-lijn...
  • Page 7 • Maak een plattegrond van het huis met alle deuren en ramen en minstens twee (2) vluchtroutes voor elke kamer. Ramen op de tweede verdieping moeten misschien van een Lamp vluchtladder (KEL15) voorzien worden. Neem contact op met uw Kidde-dealer voor meer Onderstuk Onderstuk informatie.
  • Page 8: Service En Garantie

    • Voor meer informatie over brandpreventie kunt u terecht bij de afdeling preventie van de Votre alarme à la fumée KIDDE est conçue pour détecter les produits de la combustion grâce à plaatselijke brandweer. la technique d’ionisation. Elle contient 0,9 microcurie d’américium 241, un matériau radioactif.
  • Page 9: Instructions D'installation

    0915 etc Guide 23/8/01 11:22 am Page 16 CHAMBRE CHAMBRE CHAMBRE Lors d’une fixation sur CUISINE Lors d’une fixation dans un mur, la ligne A doit un couloir, la ligne A doit être horizontale et la être parallèle au couloir.
  • Page 10 0915 etc Guide 23/8/01 11:22 am Page 18 ATTENTION ! UNE DÉTECTION PLUS PRÉCOCE DU FEU EST OBTENUE AVEC L’INSTALLATION L’alarme à la fumée est alimentée par une batterie de 9V carbone zinc (il est aussi possible D’EQUIPEMENT DE DETECTION D’INCENDIE DANS TOUTES LES PIECES ET ZONES DU LOGEMENT, d’utiliser une pile alcaline).
  • Page 11 KIDDE Safety dans le cadre de cette garantie sont limitées à la réparation et au remplacement de l’alarme ou de toute pièce dont nous pourrons constater qu’elle présente un défaut de pièces, de main •...
  • Page 12 9 volt rookalarm met batterijvoeding VOOR DE MODELLEN 0915, 0916, 0916LL & 0918 Dank u voor uw aankoop van een KIDDE rookalarm. Leest u allereerst onze gebruikshandleiding goed door alvorens het apparaat te installeren. Bewaar deze handleiding voor toekomstige raadpleging.

This manual is also suitable for:

09160916ll0918

Table of Contents