Please setup the ICAM-500 with following instruction to operating ICAM-500 in local
for troubleshooting, if user have problem to connect the ICAM-500 via host PC. Con-
tact Advantech FAE for technical support If ICAM-500 still can't be boot up and acqui-
sition after reset up the ICAM-500.
5.1

Connection for Keyboard, Mouse and Display

Insert the USB type C adapter/cable to USB type C connector directly for key-
board & mouse connection
Insert the HDMI cable to connector directly for display connection
5.2

Reconnect a Power and D I/O cable

Align the alignment pin (Cable side) with the alignment channel (Device side)
Inset the cable connector and tighten the threaded collar to fix the connection.
Plugin the power source after the M12 connector feast on the ICAM-500.
5.3

Operate the Camera Function

1.
Click Google Chrome on desktop of the ICAM-500.
2.
Enter the default IP address of the ICAM-500: 192.168.0.100:5000 or Local-
host5000
3.
Then ICAM-500 web server interface will be displayed in the Chrome browser.
5.4

BSP image flashing

1.
Connect ICAM-500 device and Host PC(X 86 with Ubuntu OS) with micro USB
cable. And connect the HDMI screen to the ICAM-500 device.