Panasonic AG-VF5P Service Manual page 53

1.5"eiectronic view finder
Table of Contents

Advertisement

Electrical Adjustment Procedures
<Recommended
(M.EQ) & Servicing Fixtures>
N o .
N AM E
1
D i g i t a l V o l t M e t e r
2
F r e q u e n c y C o u n t e r
3
R e g i s t r a t i o n C h a r t
S c r e wd r i v e r f o r
4
A d j u s t m e n t
5
C a m e r a ( - R e c o r d e r )
6
M o n i t o r
*1: Please use a plastic type screwdriver.
*2:
Supply a power and video signal to the Electric
Viewfinder.
*3:
Connect the video out of Camera (-Recorder).
<Preparation of adjustment>
1. Before start the adjustment, Set
CONTRAST, and PEAKING VR position on the
front as shown bellow.
BRIGHT
CONTRAST
45°
1. Connect the Video OUT or CAM OUT to the
monitor.
2. Set a monitor to under scanning mode.
3. Aim a camera (-recorder) at the "Registration
chart", and adjust the lens focus by the monitor
screen.
4. Adjust Zoom and camera position so that each
marker on the chart is just fit on the monitor screen
as shown bellow.
Measurement
Equipment
M o d el
V F K 0 6 7 3
A J - D 4 1 0 A
A G - D V C 2 0 0
PEAKING
90°
MIN
Marker
1. H HOLD Adjustment
Board
R e m a r k
TP
Adjust
Input
M.EQ
* 1
Spec.
1. Set a camera (-recorder) to Color Bar mode.
* 2
2. Confirm that picture on the EVF screen is locked
* 3
horizontally.
If it is not, adjust VR9001. Then again confirm that
picture on the EVF screen get stable immediately
after camera power is turned on.
2. V HOLD Adjustment
BRIGHT,
Board
TP
Adjust
Input
M.EQ
Spec.
1. Set a camera (-recorder) to Color Bar mode.
2. Confirm that picture on the EVF screen is locked
vertically.
If it is not, adjust VR9002. Then again confirm that
picture on the EVF screen get stable immediately
after camera power is turned on.
EAD-1
MAIN
EVF Screen
VR9001 [H HOLD]
Camera color bar
-----
Picture is locked horizontally
MAIN
EVF Screen
VR9002 [V HOLD]
Camera color bar
-----
Picture is locked vertically