Download Print this page

Huawei SUN2000-100KTL-M2 Quick Manual page 7

Hide thumbs Also See for SUN2000-100KTL-M2:

Advertisement

No. Cable
DC input power
4
cable
RS485
5
communications
cable
Note [1]: The value of S
same material. If the materials are different, ensure that the conductor of the PE cable with a
proper cross-sectional area produces a conductance equivalent to that of the cable specified in the
table. The specifications of the PE cable are subject to this table or calculated according to IEC
60364-5-54.
4.2
Installing a PE Cable
It is recommended that the PE cable of the solar inverter be connected to a nearby ground
point. Connect the PE points of all solar inverters in the same array to ensure equipotential
connections to PE cables.
To enhance the corrosion resistance of a ground terminal, you are advised to apply silica gel
or paint on it after connecting the PE cable.
Type
PV cable that meets the 1100 V
standard
Outdoor shielded twisted pair that
meets the local standard
is valid only if the conductors of the PE cable and AC power cable use the
p
Conductor Cross-
Sectional Area
4–6 mm
0.25–1 mm
Reserved PE point
6
Outer Diameter
2
5.5–9 mm
• One or two
communicatio
ns cables: 4–
11 mm
2
• Three
communicatio
ns cables: 4–8
mm