Installing the Cisco ISA 3000 Industrial Security Appliance
Figure 1: ISA 3000 Rear Din Mount
Caution
Do not stack any equipment on the device.
To attach the Cisco ISA 3000 to a DIN rail, follow these steps.
1. Position the rear panel of the device directly in front of the DIN rail, making sure that the DIN rail fits in
the space between the two hooks near the top of the device and the spring-loaded latch near the bottom.
2. Holding the bottom of the device away from the DIN rail, place the two hooks (1) on the back of the
device over the top of the DIN rail.
3. Push the device toward the DIN rail to cause the spring-loaded latch (2) at the bottom rear of the device
to move down, and snap into place.
Installing the Cisco ISA 3000 Industrial Security Appliance
Installing a DIN Rail
3