Controller Data - Hussmann RGD Installation & Operation Manual

Upright deli case
Table of Contents

Advertisement

Function
Normal Opertion
Temperature (Set Point)
Thermostat
Differential
Max. limitation of setpoint setting
Min. limitation of setpoint setting
Temperature Unit (C/F)
Manual Service (-1), Stop Regulation (0),
Start Regulation (1)
Alarm
Compressor
Defrost
Defrost Method (EL/Gas/Brine)
Defrost Stop Temperature
Interval between defrost starts (Hours)
Maximum Defrost duration (Minutes)
Defrost Sensor (0=Time, 1=S5,
2=S4)
Fans
HACCP
Real Time Clock
Miscellaneous
Service

11. Controller Data

Codes
Min
Max
--
-50°C
50°C
r01
0.1K
20K
r02
-49°C
50°C
r03
-50°C
49°C
r05
°C
°F
r12
-1
1
d01
no
Gas
d02
0°C
25°C
d03
0
48
d04
0
180
d10
0
2
28
Factory Setting RGD TYPE1
2°C
24°F
2K
50°C
32°F
-50°C
24°F
°C
0
EL
6°C
48°F
8
45
0
RGD TYPE 2
24°F
8
4
32°F
20°F
°F
°F
1
1
EL
EL
48°F
6
2
25
15
0
0

Advertisement

Table of Contents
loading

Table of Contents