1.5.2 Response Time

1.5.2-1 Time interval (T1) between external device communication and
IJ printer response
(1) When Print format is set to "Individual"

Time interval (T1) between external device communication and IJ printer response

No. Transmission type
1 Print description
2 Print data recall
Print data
3
registration
4
5
Print conditions
6
7
Free layout
User pattern
8
character
9 Date/time setup
10 Remote operation
●When the Print format is set to "Individual" and Free layout transmission is made, a communication error
will occur.
*1 For "t=fixed" and "t=async.", see "Communication User's Manual (Common)".
*2 When there is a data matrix, QR code, Micro QR, GS1 Data Bar setting and Dotcode setting,
the time is as follows.
*3 If time changes just before ACK transmission, ACK transmission may be delayed about 20 ms.
Baud rate (bps)
150 to 1200
2400 to 115200
Conditions
The print message transfer
ACK condition is t=fixed.
The print message transfer
ACK condition is t=async.
Print specifications
Print format
Line count/print format
uniformity
Format setup change
Error reset
Operation start, operation
stop, deflection voltage
control
T0 Maximum time (ms)
10
5
T1 Maximum Time(ms)
Within 24 items
25 items or more
20
+ 55
10
10
20
1000
10
20
20
100
15×N + 10
5
15
100
M: Number of communication characters
N: Number of communication patterns
52
Remarks
55
*1
*1
+ 105
*2
30
1000
10
50
50
100
15×N + 10
5
*3
15
100

Advertisement