Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The instruction manuals on our website www.kobold.com are always for currently manufactured version of our products. Due to technical changes, the instruction manuals available online may not always correspond to the product version you have purchased.
NBK-Rx200Nx 4. Regulation Use Any use of the Level switch, model: NBK-RV200NC/NO or NBK-RN200NC/NO, which exceeds the manufacturer’s specification, may invalidate its warranty. Therefore, any resulting damage is not the responsibility of the manufacturer. The user assumes all risk for such usage. page 4 NBK-Rx200Nx K03/0323...
"memorised". Because of its low mass switching element this level switch is particularly suitable in installations with strong vibrations, The level switch type NBK-RV200NO/NC is reduced to a Reed miniswitch for low level AC/DC loads. The level switch type NBK-RN200NO/NC is additional equipped with 2 resistors to meet the 2-wire NAMUR specification (Rs=1k, Rp=10k).
NBK-Rx200Nx 6. Mechanical Connection The mounting of the switch is done by an pipe clamp as shown in Fig. 3/4. The cable gland is directed downwards in any case. The switching point is situated nearby the middle of the box. The heat protection is situated between the switch box and the mounting bracket.
NBK-Rx200Nx 7. Electrical connection Authorised skilled personnel only recommended to connect the electrical circuits. small load NBK- fig. 5: electrical connection RV200NO/NC NBK-RV200NO/NC NBK- fig. 6: electrical connection RN200NO/NC NBK-RN200NO/NC fig. 7: safety precautions for Reed switch in DC and AC application...
NBK-Rx200Nx 8. Technical Information Operating instructions, data sheet, approvals and further information via the QR code on the device or via www.kobold.com 9. Order Codes Operating instructions, data sheet, approvals and further information via the QR code on the device or via www.kobold.com 10.
NBK-Rx200Nx 11. Disposal Note! • Avoid environmental damage caused by media-contaminated parts • Dispose of the device and packaging in an environmentally friendly manner • Comply with applicable national and international disposal regulations and environmental regulations. Batteries Batteries containing pollutants are marked with a sign consisting of a crossed-out garbage can and the chemical symbol (Cd, Hg, Li or Pb) of the heavy metal that is decisive for the classification as containing pollutants: 1.
NBK-Rx200Nx 12. EU Declaration of Conformance We, KOBOLD Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product: Level Switch Model: NBK-RV200NO/NC and NBK-RN200NO/NC to which this declaration relates is in conformity with the standards noted below: EN IEC 63000:2018 Technical documentation for the assessment of electrical...
Need help?
Do you have a question about the NBK-RV200NO and is the answer not in the manual?
Questions and answers