Download Print this page
Tippkemper Matrix IRS-001-LA Series Original Operating Manual

Tippkemper Matrix IRS-001-LA Series Original Operating Manual

Photoelectric sensors with analog output

Advertisement

Quick Links

Photoelectric sensors with analog output: IRS/IRN/IRD-001-LA*(-OP)
IRD-001-LA*-OP
IECEx BVS 14.0108X
0158
IECEx designation
Ex d [op is Ga] IIC T6 Gb
Ex tb [op is Da] IIIB T100°C Db IP67
II 2(1)G
II 2(1)D
Technical data
Type of Ex protection Gas, directive 2014/34/EU
Type of Ex protection Dust, directive 2014/34/EU
For use in Ex Zones
Output signal range
Voltage output, nominal range,
on white paper. A4. 80g
Current output, nominal range,
on white paper. A4. 80g
Light source
Optical aperture angle
Maximum optical radiant power
Maximum radiant power
Response time
Power up delay time
Supply voltage
Intrinsic current consumption
Maximum power dissipation
Output type, voltage, IR*-001-LAV(-OP)
Output type, current, IR*-001-LAI/LA4(-OP)
Disable-Input, only types IR*-001-LA*(-OP)-S259
Housing
Enclosure rating, according to EN 60529
Ambient working temperature range T
Storage temperature range
Relative humidity
Vibration and shock resistance
Pollution degree, according to EN 60664-1:2007
Device designation, according to EN 60947-5-2
Connection cable
Connection cable, types
IR*-001-LA*(-OP)-S259
Socket, IRS/IRN-001-LA*(-OP)-S099
Accessories, all devices
Accessories, only IRD/IRN-001-LA*-OP
Accessories, only IRN-001-LA*-OP-S099
Accessories, not included, only IRS/IRN-*-S099
Accessories, not included, all types
Options
Function and LED indication
Optical beam characteristic
Output diagram
(measured on white paper,
80g, 20cm x 30cm)
Potentiometer on MAXIMUM
Original Operating Manual:
Housing M30
• Also for using with different certificated fibre optics
• IRD: ATEX and IECEx certificated
• Types IRD: For use in Ex Zones (0),1, 2, (20), 21, 22
• Types IRN: For use in Ex Zones (1), 2, (21), 22
• With voltage or current loop output available
• Applicable for range measurement or position detection or as turbidimeter
• Applicable with glass fibre optics
Type
IRS-001-LA*
LA*= Type of analog output. LAV: Voltage output 0 ... 10V.
LAI: current loop output 0mA ... 20mA. LA4: current loop output 4mA ... 20mA
NONE
NONE
NONE
0.03VDC - 10.5VDC( Ripple:<20mV) or 0.06mA - 21mA or 4mA - 20mA
NOT LIMITED
NOT LIMITED
M30, brass Ms 58, nickel plated (optional stainless steel 1.4404, types: IR*-005-A**(-OP)-S224
IP 65
amb
3+PE x 0,5mm
,TPU, shielded, leads numbering marked, oil resistant
2
4+PE x 0,5mm
,TPU, shielded, leads numbering marked, oil resistant
2
- 2x nuts M30 (or 1 clamp on demand)
- 1x Spare safety screw with packing ring for potentiometer sealing
- 1x Safety lock device, mount at the cable connection,
- 1x Warning plate
- 1x Protection cap for the sensor socket
- Single ended cordset, types RKTS 5-298/xx or
- Additional optic, type DL-30: For range extension
- Cable length:
- IRS/IRN-001-LA*(-OP)-S099: Male connector M12: Lumberg RSF-5, 5 pins
- IRS/IRN-001-LA*(-OP)-S110: With additional optic DL30 and special reflector
- IRS/IRN-001-LA*(-OP)-S155: Response time = 1.5ms
- IRN/IRD-001-LA*(-OP)-S224: Housing stainless steel 1.4404 / 316L
- IR*-001-LA*(-OP)-S259:
- IR*-001-LA*(-OP)-S311:
- IR*-001-LA4(-OP)-S314:
- IR*-001-LA*(-OP)-S325:
Light barrier
with fibre optic
Proximity switch
Proximity switch
with fibre optic
The brightness of the LED and the
output level,
is dependant on the
quantity of the detected light.
PNP=OFF
R 25Ω
IR*-001-LAV
V-Out
2 0 ,0 0
15,0 0
10 ,0 0
5,0 0
0 ,0 0
1
3
5
7
9
ISO 9001:2015 / ATEX
II 3(2)G Ex nA [op is Gb] IIB T4 Gc, II 3(2)D Ex tc [op is Db] IIIA T135°C Dc IP67
IRN-001-LA*-OP
II 3(2)G Ex nA [op is Gb] IIB T4 Gc
II 3(2)D Ex tc [op is Db] IIIA
T135°C Dc IP67
Zones (1), 2, and (21), 22
5VDC output voltage at a distance of 10cm, adjustable
10mA output current at a distance of 10cm, adjustable
Infrared 870nm
approx.10°
<=35mW
<=5mW/mm
2
5ms (faster responde time, on request)
500ms
24VDC +-10%, Um = maximum 30VDC
max. 60mA
1.6W
PNP, output impedance appr. 25Ω, RLoad: 2kΩ to 1MΩ
NPN, output impedance appr. 500Ω, RLoad: 0Ω to 100Ω
PNP compatible, Ri 10kΩ
IP 67
-20°C up to +50°C
-20°C ... +70°C
15% ... 80%
Vibration: 30g over 20Hz to 2kHz. Shock: 100g for 3ms
4
R3A30AP1
Male connector M12, Lumberg RSF 5, 5-leads
"Do not open/close when supply voltage connected"
RKWTH 5-298/xx, Lumberg
Up to maximum 100m. Designation: IR*-005-LA*(-OP)/K:100m
With emitter disable input (DI)
Sourcing current output 4 - 20mA, max. Load 470Ω
For measurement of Turdibity of liquids 1NTU to 500NTU.
S099 + S311
Light barrier
with fibre optic
Light beam free
Proximity switch
Proximity switch
with fibre optic
No light detected. Output=OFF, LED=OFF
+24VDC
Output
0.03-
V
10.5VDC
0V (-)
11
13
15
17
19
2 1
2 3
2 5
Distance in cm
IRN-001-LA*-OP
ATEX-Kennzeichnung:
IRD-001-LA*-OP
II 2(1)G Ex d [op is Ga] IIC T6 Gb
II 2(1)D Ex tb [op is Da] IIIB
T100°C Db IP67
Zones (0),1,2 and (20),21,22
<=15mW
<=5mW/mm
2
IP67
cable for trailing, L: 3m
cable for trailing, L: 3m
for locking the connection
Light beam interrupted
+24VDC
0.06-21mA
A
(4-20mA)
R 500Ω
Output
IR*-001-LAI/LA4
I-Out
0V (-)
2 7
2 9
3 1
3 3
3 5
3 7
3 9
4 1
4 3
4 5
Page 1 of 2

Advertisement

loading
Need help?

Need help?

Do you have a question about the Matrix IRS-001-LA Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tippkemper Matrix IRS-001-LA Series

  • Page 1 ISO 9001:2015 / ATEX Original Operating Manual: Photoelectric sensors with analog output: IRS/IRN/IRD-001-LA*(-OP) IRD-001-LA*-OP Housing M30 IRN-001-LA*-OP • Also for using with different certificated fibre optics IECEx BVS 14.0108X • IRD: ATEX and IECEx certificated 0158 • Types IRD: For use in Ex Zones (0),1, 2, (20), 21, 22 •...
  • Page 2 IRN/IRD-*-LA* IRN/IRD-*-LA*-S259 Dimensions and wiring Function: Lead-No: Lead-No: IRN/IRD-001-LA*-OP-S***: +24VDC 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0...

This manual is also suitable for:

Matrix irn-001-la seriesMatrix ird-001-la series