10-830
Read the complete manual before attempting installation and
activating the system.
1. DESCRIPTION
DIN rail relay 10-830 is always used in combination with other components
from the Niko Standard Access Control range.
The relay allows the user:
• to connect the system to an additional bell, a light source, a gate control
or Nikobus via a potential free output contact.
• to connect a potential free contract (from a pushbutton or Nikobus) via
the input contact for the execution of a particular function.
It has a N.C. or N.O. contact and is equipped with a program button to
adjust the settings.

2. COMPONENTS AND INSTALLATION

➀ terminals for the bus (3- or 2-wire)
➁ terminals for the input contact
➂ program button
➃ programming status LED
➄ relay output status LED
➅ input contact status LED
➆ N.O. or N.C. output contact (max. 230V/3A)
a
b
P
This product must be
secured with a miniature
circuit breaker (MCB)
of max. 16 A in the
electrical cabinet. The
MCB rating is limited by
national installation rules
N.C. contact
Note!
Disconnect all power before installing the relay. Do not connect
the unit to the power supply until installation is complete.
18 19 20 21 22 23 24 25
14 15 16 17 18 19 20 21 22 23 24 25
3. PROGRAMMING
3.a Possible settings for the RELAY OUTPUT:
Assigning the relay output to a bell pushubtton that has not
yet been programmed.
briefly press power supply PROG
button
briefly press relay PROG button
1
2
3
4
5
6
5
6
7
8
9 10 11 12
13
18 19 20 21 22 23 24 25
14 15 16 17 18 19 20 21 22 23 24 25
briefly press bell pushbutton, ring tone sounds
relay assigned to bell pushbutton
briefly press power supply PROG
button
4
Assigning the relay output to a bell pushbutton on which an
internal unit has been programmed (not for 10-15x)
Clearing a bell pushbutton
See manual of bus power supply 10-801, 10-802 or 10-806
Assinging the relay output to an event
You can cause the relay output to switch upon the occurrence of a particular
event such as:
• pressing the floor bell pushbutton on a particular internal unit
M- P
• pressing a particular bell pushbutton
• pressing the door opener button or any other button on a particular
internal unit
• ...
The event can be taught to the relay, so that the relay will switch whenever
this particular event occurs.
Note!
or
N.O. contact
Setting the relay output activation time between 0.5s and
128s (factory setting = 1s)
power supply LED blinks
system in programming mode
relay LED blinks for 30s
7
8
9 10 11 12
13
3.b Possible settings for the INPUT CONTACT:
The input contact can be programmed so that with each closure it
performs the same action as when
• pressing a particular floor bell pushbutton
• pressing a particular bell pushbutton
• pressing the door opener button or any other button on a particular
internal unit
• ...
This action can be taught to the input contact, so that the same system
action is triggered whenever the contact closes.
power supply LED lights
Factory setting:
Closing of the input contact places the door opener commando on the
bus for the external unit with address 0.
Note! Only one action can be taught.
programming mode deactivated
STEP 1 (see above)
STEP 2 (see above)
press bell pushbutton until you hear 2 beeps followed by ring tone
1
2
6s.
2s.
relay assigned to bell pushbutton
STEP 4 (see above)
• This is only possible with the internal or external unit that
was used to teach the action to the relay.
• Only one action can be taught.
press relay PROG button until
relay LED lights
perform desired action within 30s:
press door opener button, bel lor floor pushbutton or...
briefly press relay PROG button, LED goes out
relay assigned to bus command
briefly press relay PROG button
relay LED blinks
press and hold down relay
release PROG
PROG button until the
button, LED
desired activation time is
goes out
reached
press relay PROG button until
relay LED lights
press door opener button or press floor bell pushbutton or...
(enter free bus command on service unit 10-870)
press relay PROG button until
LED goes out and lights again
3.c Restore factory settings:
To erase the programmed functionality for the relay output and the input
contact, and to reset the relay activation time to 1s, proceed as follows:
press relay PROG button until
relay LED lights
press relay PROG button until
LED goes out, lights and goes
out again

4. TECHNICAL DATA

Supply voltage: ...............................24V ± 8% (BUS power module)
Circuit breaker: ...............................maximum MCB rating 16 A*
Dimensions (in mm): .......................H85 x W18 x D65 (1E)
Weight:...........................................52g
release
Operating temperature: ...................-20 to 50°C
Current consumption when OFF: ......0.4mA (a); 1.4mA (P)
Max. current consumption: ..............0.4mA (a); 21mA (P)
Contact load: ..................................230V~ / 3A
Current across signal input: .............2.5mA
Min. action duration at signal input: ..100ms
* The MCB rating is limited by national installation rules.
Warnings regarding installation
The installation of products that will permanently be part of the electrical
installation and which include dangerous voltages, should be carried out
by a qualified installer and in accordance with the applicable regulations.
This user manual must be presented to the user. It should be included
in the electrical installation file and it should be passed on to any new
owners. Additional copies are available on the Niko website or via Niko
customer services.
CE marking
This product complies with all of the relevant European guidelines and
regulations. For radio equipment Niko llc declares that the radio equipment
in this manual conforms with the 2014/53/EU directive. The full text of
the EU declaration of conformity is available at www.niko.eu under the
product reference, if applicable.
Environment
This product and/or the batteries provided cannot be disposed of in
non-recyclable waste. Take your discarded product to a recognised collection
point. Just like producers and importers, you too play an important role in
relay activation time
the promotion of sorting, recycling and reuse of discarded electrical and
has been set
electronic equipment. To finance the rubbish collection and waste treatment,
the government levies recycling charges in certain cases (included in the
price of this product).
Support & contact
nv Niko sa
Industriepark West 40
9100 Sint-Niklaas, Belgium
www.niko.eu
EN
+32 3 778 90 80
release
perform desired action:
release
signal input
assigned to action
release
release
Factory settings
activated
support@niko.eu
PM010-83000R23055

Advertisement

loading