Means that the screen is not affected by the signal data when you connect the product to Backlight or
No Display
user connector and then 12V input power ON/OFF.
Less than Electricity
Consumption
150mA
User Connector
(C-PCB CN1) Cold
NG
soldering/Open/Short
Check
OK
Fuse(F1)
NG
Open Check
OK
C18,19,67,68,69,70
NG
Short Check
Trouble shooting
Input Current
User Connector(CN1)
Resoldering / Replace
/ Reassembly
Fuse(F1) Replace
C18,19,67,68,69,70
Resoldering / Replace
More than Electricity
Consumption
150mA
FFC(CN4,6)
Assembly / Open Check
OK
Power Block - Out Voltage
-After of Open the U9
Output Check
VCC(+3.3V)
VGL(-5.0V),VDD(+16.5V)
VGH(+24.0V)
OK
VCC Generation Block
Cold soldering/Open/
Short Check
R99, 89~93,C78~82
L1,D12
OK
VDD Generation Block
Cold soldering/Open/
Short Check
R51,53,56,57,
C57,58,C50~54,56,59
D11,L2
OK
VGH_S Generation Block
Cold soldering/Open/
Short Check
R81,84,86~88,C73~75,D15
OK
VGH Modulation Block
Cold soldering/Open/
Short Check
R76, C101, C102
OK
TCON Block(UL1)
Output Data Check
NG
FFC(CN4,6)
Reassembly / Replace
NG
U9/Under the Parts
Resoldering / Replace
Under the Parts
NG
Resoldering / Replace
Under the Parts
NG
Resoldering / Replace
Under the Parts
NG
Resoldering / Replace
NG
Under the Parts
Resoldering / Replace
NG
UL1/Under the Parts
Resoldering / Replace