Contents 0. Introduction 0.1 COP Graph 1. Installation and Connection Unit Location on Site Connection 1.3 Connecting the SPLIT Units 2. First tarting up Setting and Operation 4. Maintenance 4.1 To be checked up regularly 4.2 Leakage 4.3 Winterizing 5. Error Indications and Trouble Shooting 6.
0. Introduction Thank for buying the Proteam Heat Pump. Please read this manual, and take the advantages of the benefits this unit. Learn how to read all the information on the display. You can easily optimize the Heat Pump performance.
1. Installation and Connection Unit Location Site This unit should be installed outdoors , under special conditions also door . 2. Connect the unit to the pool pump pressure side after al filters and before any chlorinators, ozonators or dosing equipments (see next page). Place the eat ump unit as close to the filter system as possible.
1. Installation and Connection 1.2 Connection Water flowing out of filter is divided by three valves: Some water is led to the Heat Pump to be heated/cooled and then after being mixed with the water from the filter it is led back to the pool.
Page 7
1.2 Wrong Location and Connection (Examples) The unit is located too close to the wall. Wrong connection of the valves Separate valves for IN-going and OUT-going water are necessary (see p. 5).
Page 8
1.3 Installation and Connection - Split Unit Connection of the two units of the SPLIT Heat Pump Description and Location The Main Unit (the bigger cabinet) has to be located outside (under special conditions also inside - in a room with warm air continuously regenerated with energy, eg. with equipment that continuously warm the air).
Page 9
Split Heat Pump Unit Connectio Outside Unit Heat Exchanger - Inside unit (smaller cabinet) Nuts Measurement A - 22 C - 22 E - 14 B - 27 D - 24 F - 14 G - 22 use Hexagonal key 5 mm Tube connection H - 27 Connect thick tube between...
2. First starting up 1. Turn the filter pump on Check the flow Check the unit for water leak and verify flow to and from the pool. 2. Turn the unit Turn the electrical power supply with the main switch There is some delay before the fan starts running.
3. Setting and Operation 3.1 LED Controller The settings and operation of the Heat Pump are performed on the LED Controller. LED screen contains two two-digit numbers. The first number indicates operation parameter, the other gives the value of the parameter. The parameter value can be viewed while the pump is running by pressing ▲...
Page 15
Defrosting Heating Cooling Running time of the com- Temperature of the out-going Temperature of the out-going pressor after getting ice on water in heating mode. water in cooling mode. evaporator (energy collector). Range: 15 to 40 °C Range: 8 °C Range: 30-90 sec Default: 27 °C Default: 27 °C...
Page 16
Pump Current temperature of the Current temperature of the out-going water to the pool. 0 - always running (e.g. in-coming water from the because of filtering...) pool. 1 - The pump starts 60 seconds before the com- pressor starts, and stops 30 seconds after the compressor stops.
The operation pressure of the refrigerant system should be serviced only by a certified technician , preferably by a Proteam workshop. 3 IMPORTANT: Winter ing Prevent freezing: All water must be discharged from the unit before winter...
(PP25C/PP28C) (3 ph.) High/low pressure Refrigerant charge too Check through each pressure (PP10C/PP15C/ or high. Possible switch and return circuit. PP25C/PP28C) system blockage. The water-in and water- Water flow rate not Check the water flow rate or out temp.
Page 20
5. . 2 System Protection Board Malfunction Table (Only 3 phase units) Disp. Problem Reason Action Reco Resolution code description very Icing/freezing on Refrigerant temperature Unit stops, Y Reduce the amount of evaporator at the from the tube outlet is alarm the refrigerant refrigerant inlet...
Page 21
6. Connection Table 10 11 11 12 12 12 13 14 14 15 15 16 16 17 17 17 Connection legend: Symbol Meaning HEAT Underpan heat cable output: 220-240 VA PUMP Water pump: 220-240 VA Fan motor: 220-240 VA VAL2 Solenoid valve: 220-240 VA VAL1 Four-way valve of system 1 : 220-240 VA...
Page 22
6. Connection Table (Only 3 phase units) Legend: HINGH2 GND High pressure protection for system 2 (normally closed) LOW2 GND Low pressure protection for ystem 2 (normally closed) HINGH1 GND High pressure protection for ystem 1 (normally closed) LOW1 GND pressure protection for ystem 1 (normally closed) SYS GND 12V...
Page 23
6. Connection Single phase Power out (to filter pump, optionally) Power in Three phases Power in Power out (to filter pump, optionally)
Page 24
6. Connection Table PP03C/10C/15C COMP BLK RED CHILLER 300 CHILLER 300 PIPE1 PIPE1 OUTWT OUTWT INWT INWT ROOMT ROOMT RED BLU TO POWER SUPPLY TO POWER SUPPLY TO PUMP 230V/AC 230V/AC 230V/AC Wire Controller Wire Controller PASRW010/015/020/030...
Page 25
6. Connection Table PP10S/15S SWIMMING POOL HEAT PUMPWIRING DIAGRAM SWIMMING POOL HEAT PUMPWIRING DIAGRAM PAXRW020/030 PAXRW020/030 COMP CHILLER300 CHILLER300 RED BLU OUTWT INWT ROOMT PIPE1 TO POWER TO PUMP Wire Controller Wire Controller TO WATER UNIT TO WATER UNIT...
Page 26
6. Connection Table PP10S/15S TO MAIN UNIT...
Page 27
6. Connection Table PP20C COMP COMP OVERLOAD SWITCH OVERLOAD SWITCH STARTINGCAP STARTINGCAP STARTING STARTING RELAY RELAY CHILLER 300 CHILLER 300 PIPE1 OUTWT INWT ROOMT 21 22 25 26 TO POWER SUPPLY TO POWER SUPPLY TO PUMP 220-240V/AC/50Hz 220-240V/AC/50Hz 220-240V/AC/50Hz 220-240V/AC/50Hz Wire Controller Wire Controller PASRW040...
Page 28
6. Connection Table PP25C/28C SWIMMING POOL HEATER WIRING DIAGRAM PASRW050S/060S PROTECT OVERLOAD SWITH OVERLOAD SWITH WH BLK BLK RD 4way valve1 CHILLER 300 CHILLER 300 ROOMT PIPE1 OUTWT INWT Flow switch Wire Controller To water pump To water pump To three phase power...
Page 30
6. Connection Table PP25S/28S TO MAIN UNIT...
Page 31
Explo de View and Spare Parts PP07C, PP10C, PP15C Pos. Part Name Pos. Part Name Top cover Heat exchanger Back web Water flow switch Back holder Right panel Motor bracket Box for wire controller Left web LED-wire controller Fan motor Comp.
Page 32
Explo de View and Spare Parts PP20C Pos. Part name Pos. Part name Top cover Terminal 6 Condenser Controlling box Motor bracket Terminal Back holder 4-way valve Left web Pressure switch (mid) Fan motor Pressure switch (low) Axis blower fan Pressure switch (high) Front panel Water flow switch...
Page 33
Explo de View and Spare Parts PP , PP10S Main unit Pos. Part name Pos. Part name Front panel Right panel Middle panel Electrical cover Electrical support 3/8 “ valve Main controller /8 “ valve way valve Terminal Back web Rela Temperature sensor Compressor capacitor...
Page 34
Explo de View and Spare Parts PP 10S, PP15S - Water Unit Pos. Part name Pos. Part name anel Panel Terminal wire controller Electrical box bracket Water outlet temp. sensor Titanium heat exchanger Water inlet temp. sensor Chassis Top cover Water flow switch...
Page 36
7.1 Unit Specifications - Dimensions - Compact Models THIS SIDE AIR OUT AIR IN Unit Specifications - Dimensions [mm] Type PP03C PP10C P 1 C PP20C PP25C PP28C Dimensions 1260 1260 1230 1230 1000 1000 1110 1120 1120...
Page 37
7.2 Unit Specifications - Dimensions - Split Models WATER UNIT MAIN UNIT Unit Specifications - Dimensions [mm] Type PP10S P 5S Dimensions Main unit Water unit Main unit Water unit...
Page 38
8 Our Production-Delivery Program Input Recomended Heated May to Sept. Heated March to Nov. Model Pool size [m2/ft2] Pool size [m2/ft2] 10 kW PP10C 30/300 20/200 15 kW PP15C 50/500 30/300 20 kW PP20C 80/800 50/500 28 kW PP28C3 three phase...